Influence of Anatomical Parameters on the Dimensions of the Subantral Space and Sinus Mucosa Thickening after Sinus Floor Elevation. A Retrospective Cone Beam Computed Tomography Study.

Omori Yuki, Nakajima Yasushi, Imai Hideki, Yonezawa Daichi, Ferri Mauro, Apaza Alccayhuaman Karol Alí, Botticelli Daniele

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Various anatomical parameters might influence the surgical approach for maxillary sinus floor elevation. The objective of the present study was to retrospectively evaluate the influence of anatomical parameters on the dimensions of the subantral space and of the sinus mucosa thickening after sinus floor elevation.

MATERIAL AND

METHODS

Seventy-eight maxillary sinuses in sixty-five patients were evaluated on cone beam computed tomographies taken before surgery and after one week (t1w) and nine months (t9m). Several parameters such as the distance XF between an axis parallel to the base of the nose (X-axes) and the sinus floor (F) were correlated with the height gain (IF) at t1w and t9m and the post-surgical edema.

RESULTS

A weak significant positive correlation was observed between height gain vs. sinus height of interest (XF), the balcony, and the sinus floor angle. The post-surgical edema was influenced by the initial mucosa thickness and the xenograft used.

CONCLUSIONS

Various parameters might affect height gain and sinus mucosa thickening after sinus floor elevation. The height of interest, the balcony, and the sinus floor angle showed significant correlations with height gain. The initial thickness of the mucosa and the biomaterial used influenced the post-surgical edema.

Для цитирования: Omori Yuki, Nakajima Yasushi, Imai Hideki, Yonezawa Daichi, Ferri Mauro, Apaza Alccayhuaman Karol Alí, Botticelli Daniele. Influence of Anatomical Parameters on the Dimensions of the Subantral Space and Sinus Mucosa Thickening after Sinus Floor Elevation. A Retrospective Cone Beam Computed Tomography Study.. Dentistry journal. 2021. DOI: 10.3390/dj9070076.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.