DOI 10.1097/00019501-200609000-00009
Contrast enhancement of coronary atherosclerotic plaque: a high-resolution, multidetector-row computed tomography study of pressure-perfused, human ex-vivo coronary arteries.
Аннотация
OBJECTIVES
The objective of this study was to investigate the effect of contrast injection on atherosclerotic coronary plaque attenuation measured using multidetector-row computed tomography.
BACKGROUND
Recent multidetector-row computed tomography studies have described the characterization of coronary atherosclerotic plaque on the basis of Hounsfield unit values. The influence of contrast injection on the attenuation of individual plaque components, however, is unknown.
METHODS
Using a pressurized perfusion system, 10 human coronary arteries were examined postmortem with multidetector-row computed tomography and histology. Pre-enhanced, peak-enhanced, and delayed enhanced multidetector-row computed tomography images were acquired during continuous perfusion of the vessel. A total of 37 focal atherosclerotic plaques were identified. Vessel wall attenuation was measured from multidetector-row computed tomography images during all three enhancement phases. On the basis of the histology, plaques were categorized as noncalcified (predominantly fibrous or predominantly fibrofatty), mixed calcified (calcified fibrous or calcified necrotic core), or densely calcified. The mean Hounsfield unit was compared among contrast phases for all plaques and in plaque subgroups.
RESULTS
We observed contrast enhancement of atherosclerotic plaques within the vessel wall. For noncalcified plaques including both fibrous and fibrofatty plaques, the mean Hounsfield unit of the vessel wall during and after contrast injection exceeded the mean value before injection (t-test, P<0.002).
CONCLUSION
The present study demonstrates that intra-arterial injection of iodinated contrast agent results not only in luminal enhancement but also in atherosclerotic plaque enhancement in pressure-perfused coronary arteries imaged ex vivo. Plaque enhancement should be considered when characterizing plaque components on the basis of Hounsfield unit with multidetector-row computed tomography.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.