König Sebastian, Ueberham Laura, Müller-Röthing René, Wiedemann Michael, Ulbrich Michael, Sause Armin, Tebbenjohanns Jürgen, Schade Anja, Shin Dong-In, Staudt Alexander, Andrié René, Neuser Hans, Kuhlen Ralf, Arya Arash, Hindricks Gerhard, Bollmann Andreas

СтатьяПеревод пока не подготовлен

Аннотация

AIMS: Catheter ablation (CA) of ventricular arrhythmias is one of the most challenging electrophysiological interventions with an increasing use over the last years. Several benefits must be weighed against the risk of potentially life-threatening complications which necessitates a steady reevaluation of safety endpoints. Therefore, the aims of this study were (i) to investigate overall in-hospital mortality in patients undergoing such procedures and (ii) to identify variables associated with in-hospital mortality in a German-wide hospital network.

METHODS AND

RESULTS

Between January 2010 and September 2018, administrative data provided by 85 Helios hospitals were screened for patients with main or secondary discharge diagnosis of ventricular tachycardia (VT) or premature ventricular contractions (PVCs) in combination with an arrhythmia-related CA using ICD- and OPS codes. In 5052 cases (mean age 60.9 ± 14.3 years, 30.1% female) of 30 different hospitals, in-hospital mortality was 1.27% with a higher mortality in patients ablated for VT (1.99%, n = 2, 955) compared to PVC (0.24%, n = 2, 097, P < 0.01). Mortality rates were 2.06% in patients with ischaemic heart disease (IHD, n = 2, 137), 1.47% in patients with non-ischaemic structural heart disease (NIHD, n = 1, 224), and 0.12% in patients without structural heart disease (NSHD, n = 1, 691). Considering different types of hospital admission, mortality rates were 0.35% after elective (n = 2, 825), 1.60% after emergency admission/hospital transfer <24 h (n = 1, 314) and 3.72% following delayed hospital transfer >24 h after initial admission (n = 861, P < 0.01 vs. elective admission and emergency admission/hospital transfer <24 h). In multivariable analysis, a delayed hospital transfer >24 h [odds ratio (OR) 2.28, 95% confidence interval (CI) 1.59-3.28, P < 0.01], the occurrence of procedure-related major adverse events (OR 6.81, 95% CI 2.90-16.0, P < 0.01), Charlson Comorbidity Index (CCI, OR 2.39, 95% CI 1.56-3.66, P < 0.01) and its components congestive heart failure (OR 8.04, 95% CI 1.71-37.8, P < 0.01), and diabetes mellitus (OR 1.59, 95% CI 1.13-2.22, P < 0.01) were significantly associated with in-hospital death.

CONCLUSIONS

We reported in-hospital mortality rates after CA of ventricular arrhythmias in the largest multicentre, administrative dataset in Germany which can be implemented in quality management programs. Aside from comorbidities, a delayed hospital transfer to a CA performing centre is associated with an increased in-hospital mortality. This deserves further studies to determine the optimal management strategy.

Для цитирования: König Sebastian, Ueberham Laura, Müller-Röthing René, Wiedemann Michael, Ulbrich Michael, Sause Armin, Tebbenjohanns Jürgen, Schade Anja, Shin Dong-In, Staudt Alexander, Andrié René, Neuser Hans, Kuhlen Ralf, Arya Arash, Hindricks Gerhard, Bollmann Andreas. Catheter ablation of ventricular arrhythmias and in-hospital mortality: insights from the German-wide Helios hospital network of 5052 cases.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2020. DOI: 10.1093/europace/euz260.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.