MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/europace/euz229

Медицинская библиотека · Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2019

How to perform electroanatomic mapping-guided cardiac resynchronization therapy using Carto 3 and ESI NavX three-dimensional mapping systems.

Huang Henry D, Sharma Parikshit S, Nayak Hemal M, Serafini Nicholas, Trohman Richard G

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

AIMS: To examine the feasibility and safety of a novel protocol for low fluoroscopy, electroanatomic mapping (EAM)-guided Cardiac resynchronization therapy with a defibrillator (CRT-D) implantation and using both EnSite NavX (St. Jude Medical, St. Paul, MN, USA) and Carto 3 (Biosense Webster, Irvine, CA, USA) mapping systems.

METHODS AND

RESULTS

Twenty consecutive patients underwent CRT implantation using either a conventional fluoroscopic approach (CFA) or EAM-guided lead placement with Carto 3 and EnSite NavX mapping systems. We compared fluoroscopy and procedural times, radiopaque contrast dose, change in QRS duration pre- and post-procedure, and complications in all patients. Fluoroscopy time was 86% lower in the EAM group compared to the conventional group [mean 37.2 min (CFA) vs. 5.5 min (EAM), P = 0.00003]. There was no significant difference in total procedural time [mean 183 min (CFA) vs. 161 min (EAM), P = 0.33] but radiopaque contrast usage was lower in the EAM group [mean 16 mL (CFA) vs. 4 mL (EAM), P = 0.006]. Likewise, there was no significant change in QRS duration with BiV pacing between the groups [mean -13 (CFA) vs. -25 ms (EAM), P = 0.09].

CONCLUSION

Electroanatomic mapping-guided lead placement using either Carto or ESI NavX mapping systems is a feasible alternative to conventional fluoroscopic methods for CRT-D implantation utilizing the protocol described in this study.

Для цитирования: Huang Henry D, Sharma Parikshit S, Nayak Hemal M, Serafini Nicholas, Trohman Richard G. How to perform electroanatomic mapping-guided cardiac resynchronization therapy using Carto 3 and ESI NavX three-dimensional mapping systems.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2019. DOI: 10.1093/europace/euz229.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.