DOI 10.4097/kjae.2017.70.6.648
Humble Foley's catheter to the rescue in a case of T-tube insertion: a case report.
Аннотация
The Montgomery T-tube poses a challenge to anesthesiologists because of loss of anesthetic gases through the open proximal end of the vertical limb and lack of standard anesthesia circuit connectors. Here, we present a case of a 25-year-old woman with a reported history of accidental strangulation 18 months previously. The patient had a metallic tracheostomy tube in situ due to the development of tracheal stenosis. Computed tomography showed significant narrowing in a 7-8-mm segment, 2 cm proximal to the tracheostomy tube in situ. She was scheduled for tracheal reconstruction surgery and T-tube insertion due to persistent subglottic stenosis. In this case, the Foley's catheter, which was inserted into the glottis orally, not only aided easy insertion of the T-tube into the trachea through the tracheal stoma, but also enabled us to stop the loss of anesthetic gases through the proximal vertical limb of the T-tube.