MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajem.2017.09.050

Медицинская библиотека · The American journal of emergency medicine · 2017

Effect of the Macintosh curved blade size on direct laryngoscopic view in edentulous patients.

Kim Hyerim, Chang Jee-Eun, Han Sung-Hee, Lee Jung-Man, Yoon Soohyuk, Hwang Jin-Young

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

In the present study, we compared the laryngoscopic view depending on the size of the Macintosh curved blade in edentulous patients.

METHODS

Thirty-five edentulous adult patients scheduled for elective surgery were included in the study. After induction of anesthesia, two direct laryngoscopies were performed alternately using a standard-sized Macintosh curved blade (No. 4 for men and No. 3 for women) and smaller-sized Macintosh curved blade (No. 3 for men and No. 2 for women). During direct laryngoscopy with each blade, two digital photographs of the lateral view were taken when the blade tip was placed in the valleculae; the laryngoscope was lifted to achieve the best laryngeal view. Then, the best laryngeal views were assessed using the percentage of glottic opening (POGO) score. On the photographs of the lateral view of direct laryngoscopy, the angles between the line extending along the laryngoscopic handle and the horizontal line were measured.

RESULTS

The POGO score was improved with the smaller-sized blade compared with the standard-sized blade (87.3% [11.8%] vs. 71.3% [20.0%], P<0.001, respectively). The angles between the laryngoscopic handle and the horizontal line were greater with the smaller-sized blade compared to the standard-sized blade when the blade tip was placed on the valleculae and when the laryngoscope was lifted to achieve the best laryngeal view (both P<0.001).

CONCLUSIONS

Compared to a standard-sized Macintosh blade, a smaller-sized Macintosh curved blade improved the laryngeal exposure in edentulous patients.

Для цитирования: Kim Hyerim, Chang Jee-Eun, Han Sung-Hee, Lee Jung-Man, Yoon Soohyuk, Hwang Jin-Young. Effect of the Macintosh curved blade size on direct laryngoscopic view in edentulous patients.. The American journal of emergency medicine. 2017. DOI: 10.1016/j.ajem.2017.09.050.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.