MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/14767058.2024.2370398

Медицинская библиотека · The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians · 2024

Effect of dural puncture epidural block technique on fetal heart rate variability during labor analgesia.

Zhang Bo, Xu Mengting, Pan Chao, Chen Nan, Shi Liping, Zhou Yongxin, Liu Tao

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To explore the effect of dural puncture epidural (DPE) block technique on fetal heart rate variability (HRV) during labor analgesia.

METHODS

Sixty full-term primiparas who were in our hospital from April 2021 to October 2021 were selected and randomized into epidural analgesia (CEA) and dural puncture epidural analgesia (DPEA) groups (n = 30). After a successful epidural puncture, routine epidural catheter (EC) was performed in CEA group, and spinal anesthesia needle (as an EC) was used to puncture the dura mater to subarachnoid space in DPE group. Anesthetics were injected through EC. The time when the temperature sensation plane reached T10 (W1) and visual analog pain score (VAS), baseline heart rate score, amplitude variation score, cycle variation score, acceleration score, deceleration score, and total score of the first contraction after W1 were recorded. Apgar scores at 1 min, 5 min, and 10 min of neonates after delivery were recorded.

RESULTS

The onset time of anesthesia in CEA group was significantly longer than that in DPEA group (p < .05). However, there are no significant differences in W1, VAS, baseline heart rate score, amplitude variation score, cycle variation score, acceleration score, deceleration score, and total score of the first contraction after W1 between the two groups (p > .05). Moreover, the Apgar scores at 1 min, 5 min and 10 min of neonates after delivery were not notably different between the two groups (p > .05).

CONCLUSION

Compared with CEA, DPE block technique in labor analgesia relieves maternal pain without adverse effects on fetal HRV and newborns.

Для цитирования: Zhang Bo, Xu Mengting, Pan Chao, Chen Nan, Shi Liping, Zhou Yongxin, Liu Tao. Effect of dural puncture epidural block technique on fetal heart rate variability during labor analgesia.. The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians. 2024. DOI: 10.1080/14767058.2024.2370398.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.