Медицинская библиотека · Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society · 2024

Direct (D)-Wave Monitoring Enhancement With Subdural Electrode Placement: A Case Series.

Shah Harshal A, Chen Adrian, Green Ross, Ber Roee, D'Amico Randy S, Sciubba Daniel M, Lo Sheng-Fu Larry, Silverstein Justin W

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Direct-wave (D-wave) neuromonitoring is a direct measure of corticospinal tract integrity that detects potential injury during spinal cord surgery. Epidural placement of electrodes used for D-wave measurements can result in high electrical impedances resulting in substantial signal noise that can compromise signal interpretation. Subdural electrode placement may offer a solution.

METHODS

Medical records for consecutive patients with epidural and subdural D-wave monitoring were reviewed. Demographic and clinical information including preoperative and postoperative motor strength were recorded. Neuromonitoring charts were reviewed to characterize impedances and signal amplitudes of D-waves recorded epidurally (before durotomy) and subdurally (following durotomy). Nonparametric statistics were used to compare epidural and subdural D-waves.

RESULTS

Ten patients (50% women, median age 50.5 years) were analyzed, of which five patients (50%) were functionally independent (modified McCormick grade ≤ II) preoperatively. D-waves were successfully acquired by subdural electrodes in eight cases and by epidural electrodes in three cases. Subdural electrode placement was associated with lower impedance values ( P = 0.011) and a higher baseline D-wave amplitude ( P = 0.007) relative to epidural placement. No association was observed between D-wave obtainability and functional status, and no adverse events relating to subdural electrode placement were encountered.

CONCLUSIONS

Subdural electrode placement allows successful D-wave acquisition with accurate monitoring, clearer waveforms, and a more optimal signal-to-noise ratio relative to epidural placement. For spinal surgeries where access to the subdural compartment is technically safe and feasible, surgeons should consider subdural placement when monitoring D-waves to optimize clinical interpretation.

Для цитирования: Shah Harshal A, Chen Adrian, Green Ross, Ber Roee, D'Amico Randy S, Sciubba Daniel M, Lo Sheng-Fu Larry, Silverstein Justin W. Direct (D)-Wave Monitoring Enhancement With Subdural Electrode Placement: A Case Series.. Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society. 2024. DOI: 10.1097/wnp.0000000000001100.