DOI 10.1097/wnp.0000000000001100
Direct (D)-Wave Monitoring Enhancement With Subdural Electrode Placement: A Case Series.
Аннотация
PURPOSE: Direct-wave (D-wave) neuromonitoring is a direct measure of corticospinal tract integrity that detects potential injury during spinal cord surgery. Epidural placement of electrodes used for D-wave measurements can result in high electrical impedances resulting in substantial signal noise that can compromise signal interpretation. Subdural electrode placement may offer a solution.
METHODS
Medical records for consecutive patients with epidural and subdural D-wave monitoring were reviewed. Demographic and clinical information including preoperative and postoperative motor strength were recorded. Neuromonitoring charts were reviewed to characterize impedances and signal amplitudes of D-waves recorded epidurally (before durotomy) and subdurally (following durotomy). Nonparametric statistics were used to compare epidural and subdural D-waves.
RESULTS
Ten patients (50% women, median age 50.5 years) were analyzed, of which five patients (50%) were functionally independent (modified McCormick grade ≤ II) preoperatively. D-waves were successfully acquired by subdural electrodes in eight cases and by epidural electrodes in three cases. Subdural electrode placement was associated with lower impedance values ( P = 0.011) and a higher baseline D-wave amplitude ( P = 0.007) relative to epidural placement. No association was observed between D-wave obtainability and functional status, and no adverse events relating to subdural electrode placement were encountered.
CONCLUSIONS
Subdural electrode placement allows successful D-wave acquisition with accurate monitoring, clearer waveforms, and a more optimal signal-to-noise ratio relative to epidural placement. For spinal surgeries where access to the subdural compartment is technically safe and feasible, surgeons should consider subdural placement when monitoring D-waves to optimize clinical interpretation.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.