m+Medelevator.RU
← Поиск публикаций
The Annals of thoracic surgery · 2002

C1-esterase inhibitor reduces reperfusion injury after lung transplantation.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Scherer Mirela, Demertzis Stefanos, Langer Frank, Moritz Anton, Schäfers Hans-Joachim

Аннотация

BACKGROUND: Activation of the complement system and polymorphonuclear neutrophilic leukocytes plays a major role in mediating reperfusion injury after lung transplantation. We hypothesized that early interference with complement activation would reduce lung reperfusion injury after transplantation.

METHODS: Unilateral left lung autotransplantation was performed in 6 sheep. After hilar stripping the left lung was flushed with Euro-Collins solution and preserved for 2 hours in situ at 15 degrees C. After reperfusion the right main bronchus and pulmonary artery were occluded, leaving the animal dependent on the reperfused lung (reperfused group). C1-esterase inhibitor group animals (n = 6) received 200 U/kg body weight of C1-esterase inhibitor as a short infusion, half 10 minutes before, the other half 10 minutes after reperfusion. Controls (n = 6) underwent hilar preparation only. Pulmonary function was assessed by alveolar-arterial oxygen difference and pulmonary vascular resistance. The release of beta-N-acetylglucosaminidase served as indicator of polymorphonuclear neutrophilic leukocyte activation. Extravascular lung water was an indicator for pulmonary edema formation. Biopsy specimens were taken from all groups 3 hours after reperfusion for light and electron microscopy.

RESULTS: In the reperfused group, alveolar-arterial oxygen difference and pulmonary vascular resistance were significantly elevated after reperfusion. All animals developed frank alveolar edema. The biochemical marker beta-N-acetylglucosaminidase showed significant leukocyte activation. In the C1-esterase inhibitor group, alveolar-arterial oxygen difference, pulmonary vascular resistance, and the level of polymorphonuclear neutrophilic leukocyte activation were significantly lower.

CONCLUSIONS: Treatment with C1-esterase inhibitor reduces reperfusion injury and improves pulmonary function in this experimental model.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты