PURPOSE: To assess the results of treatment with balloon dilation and metallic Z stents in patients with tuberculous stenosis of the left main bronchus.
MATERIALS AND METHODS: Nineteen patients with tuberculous stenosis of the left main bronchus were treated with balloon (n = 15) and self-expanding metallic Z stents (n = 4). Respiratory status and pulmonary function tests were followed up for 2-90 months.
RESULTS: In the balloon group, improvements in dyspnea occurred in 73% (11 of 15 patients) immediately, 73% after 1 month, 73% after 6 months, 64% after 1 year, 64% after 3 years, and 42% after 6 years (Kaplan-Meier method). Improvement of pulmonary function (FEV1 or FVC) was achieved in 62% (eight of 13) after 1 year. In the stent group, immediate improvements of dyspnea or pulmonary function occurred in all patients. However, fracture of the stents occurred in two patients, at 4 and 18 months, respectively. Occlusion of the lumen of the stent by granulation tissue occurred in another at 18 months.
CONCLUSION: Balloon dilation can be an effective method for the treatment of tuberculous stenosis of the main bronchus. Metallic Z stents should be used cautiously because of their problems of mechanical durability and overgrowth of granulation tissue.
MATERIALS AND METHODS: Nineteen patients with tuberculous stenosis of the left main bronchus were treated with balloon (n = 15) and self-expanding metallic Z stents (n = 4). Respiratory status and pulmonary function tests were followed up for 2-90 months.
RESULTS: In the balloon group, improvements in dyspnea occurred in 73% (11 of 15 patients) immediately, 73% after 1 month, 73% after 6 months, 64% after 1 year, 64% after 3 years, and 42% after 6 years (Kaplan-Meier method). Improvement of pulmonary function (FEV1 or FVC) was achieved in 62% (eight of 13) after 1 year. In the stent group, immediate improvements of dyspnea or pulmonary function occurred in all patients. However, fracture of the stents occurred in two patients, at 4 and 18 months, respectively. Occlusion of the lumen of the stent by granulation tissue occurred in another at 18 months.
CONCLUSION: Balloon dilation can be an effective method for the treatment of tuberculous stenosis of the main bronchus. Metallic Z stents should be used cautiously because of their problems of mechanical durability and overgrowth of granulation tissue.