MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/bjs.5473

Медицинская библиотека · The British journal of surgery · 2006

Proximal loop jejunostomy is a useful adjunct in the management of multiple intestinal suture lines in the septic abdomen.

Shetty V, Teubner A, Morrison K, Scott N A

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Bowel repair in the septic abdomen can be problematic. This study investigated the use of a proximal loop jejunostomy to protect injured or fistulated bowel that had been returned to the abdomen after repair and/or anastomosis.

METHODS

Ten patients who underwent laparotomy for intra-abdominal sepsis and/or fistulation, followed by distal enteric repair and/or anastomosis and construction of a proximal defunctioning loop jejunostomy, were studied retrospectively. Seven patients had 21 intestinal suture lines returned to the peritoneal cavity in the presence of intra-abdominal sepsis (14 anastomoses, two enterotomy closures and five serotomy repairs). Two patients had a difficult relaparotomy for pelvic abscess (two distal anastomoses, one enterotomy closure and three serotomy repairs). The final patient had pelvic sepsis and radiation enteritis; the distal anastomosis was defunctioned by a loop jejunostomy.

RESULTS

The median distance from the duodenojejunal flexure to the loop stoma was 80 (range 30-170) cm. All jejunostomies were closed via a local approach, a median of 11 (range 9-18) months after formation. There was no significant postoperative morbidity and no postoperative death. At a median follow-up of 7 (range 0.5-56) months eight patients had no requirement for nutritional support.

CONCLUSION

Use of a loop jejunostomy to protect suture lines in the septic abdomen justifies consideration of this procedure in selected patients.

Для цитирования: Shetty V, Teubner A, Morrison K, Scott N A. Proximal loop jejunostomy is a useful adjunct in the management of multiple intestinal suture lines in the septic abdomen.. The British journal of surgery. 2006. DOI: 10.1002/bjs.5473.