MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5507/bp.2014.052

Медицинская библиотека · Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia · 2014

Selected ⁶⁸Ga-siderophores versus ⁶⁸Ga-colloid and ⁶⁸Ga-citrate: biodistribution and small animal imaging in mice.

Petrik Milos, Vlckova Adela, Novy Zbynek, Urbanek Lubor, Haas Hubertus, Decristoforo Clemens

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

(68)Ga-triacetylfusarinine C (TAFC) and (68)Ga-ferrioxamine E (FOXE) show great potential to be used as highly sensitive and selective tracers for Aspergillus infection imaging. Here we report on a comparison of the ex vivo biodistribution and small animal imaging of (68)Ga-TAFC and (68)Ga-FOXE versus (68)Ga-colloid and (68)Ga-citrate as unspecific control in mice.

METHODS

The radiochemical purity of tested (68)Ga labelled tracers was determined by RP-HPLC or ITLC-SG. Ex vivo biodistribution was studied in normal DBA/2 mice 30 min and 90 min p.i. Static and dynamic imaging were performed using µPET/CT.

RESULTS

(68)Ga-TAFC and (68)Ga-FOXE showed rapid renal excretion and low blood values even 90 min p.i. (68)Ga-TAFC showed almost no retention in other organs while (68)Ga-FOXE displayed some uptake in gastrointestinal tract. (68)Ga-colloid and (68)Ga-citrate revealed significantly different ex vivo biodistribution. (68)Ga-colloid showed pronounced radioactivity retention in the liver, while (68)Ga-citrate displayed high blood values and significant retention of radioactivity in highly perfused organs.

CONCLUSIONS

From the results, both (68)Ga-TAFC and (68)Ga-FOXE have excellent and significantly different in vivo behaviour compared to (68)Ga-colloid and (68)Ga-citrate. (68)Ga-TAFC in particular confirmed its great potential use as a specific tracer for Aspergillus infection imaging.

Для цитирования: Petrik Milos, Vlckova Adela, Novy Zbynek, Urbanek Lubor, Haas Hubertus, Decristoforo Clemens. Selected ⁶⁸Ga-siderophores versus ⁶⁸Ga-colloid and ⁶⁸Ga-citrate: biodistribution and small animal imaging in mice.. Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia. 2014. DOI: 10.5507/bp.2014.052.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.