MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/bmc.1145

Медицинская библиотека · Biomedical chromatography : BMC · 2009

Ultratrace analysis of uracil and 5-fluorouracil by molecularly imprinted polymer brushes grafted to silylated solid-phase microextraction fiber in combination with complementary molecularly imprinted polymer-based sensor.

Prasad Bhim Bali, Tiwari Khushaboo, Singh Meenakshi, Sharma Piyush Sindhu, Patel Amit Kumar, Srivastava Shrinkhala

СтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод пока не подготовлен

Аннотация

Main inborn errors of metabolism diagnosable through uracil (Ura) analysis and the therapeutic monitoring of toxic 5-fluorouracil (5FU) in dihydro pyrimidine dehydrogenase (DPD) deficient patients require a sensitive, reproducible, selective and accurate method. In this work, an artificial receptor in the format of molecularly imprinted polymer (MIP) brush 'grafted to' the surface of sol-gel immobilized on cost-effective homemade solid-phase microextraction (SPME) fibers, individually imprinted with either of Ura and 5FU, was used in combination with a voltammetric sensor duly modified with the same MIP. This combination provided up to 10- and 8.4-fold preconcentrations of Ura and 5FU, respectively, which was more than sufficient for achieving stringent detection limits in the primitive diagnosis of uracil disorders and fluoropyrimidine toxicity in DPD-deficient patients. The proposed method permits the assessment of Ura and 5FU plasma concentrations with detection limits pf 0.0245 and 0.0484 ng mL(-1) (RSD = 1.0-2.5%, S/N = 3), respectively, without any problems of non-specific false-positives and cross-reactivities in complicated matrices of biological samples.

Для цитирования: Prasad Bhim Bali, Tiwari Khushaboo, Singh Meenakshi, Sharma Piyush Sindhu, Patel Amit Kumar, Srivastava Shrinkhala. Ultratrace analysis of uracil and 5-fluorouracil by molecularly imprinted polymer brushes grafted to silylated solid-phase microextraction fiber in combination with complementary molecularly imprinted polymer-based sensor.. Biomedical chromatography : BMC. 2009. DOI: 10.1002/bmc.1145.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.