MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.biomaterials.2025.123253

Медицинская библиотека · Biomaterials · 2025

Phase-adapted metal ion supply for spinal cord repair with a Mg-Zn incorporated chimeric microsphere.

Liu Xiangyu, Ma Biao, Hu Sihan, Li Dandan, Pan Chun, Xu Zhuobin, Chen Hao, Wang Yongxiang, Wang Huihui

СтатьяПеревод пока не подготовлен

Аннотация

Dynamic alterations in metal ion concentrations are observed in the pathological process of spinal cord injury (SCI). Hence, strategically supplying metal ions in a phase-adapted manner is promising to facilitate injured spinal cord repair by preventing pathological damage. To achieve this, a chimeric hydrogel microsphere with Mg2+-crosslinked methacrylate gelatin as the "shell" and Zn2+-loaded poly (lactic-co-glycolic acid) (PLGA) as the "core" was designed. The chimeric microspheres allow continuous delivery of Mg2+ or Zn2+ at the exact required phase in SCI pathological process. Early release of Mg2+ reduced inflammation by diminishing the secretion of proinflammatory cytokines due to changes in macrophage polarization, which further suppressed scar formation to create an ideal space for neural regeneration. The subsequently released Zn2+ at the late phase effectively promoted neural cell proliferation and regeneration, which was accompanied by activation of mature neurons, interneurons, and motor neurons, leading to significant behavioral recovery. Thus, this study underscores the critical role of metal ions at different phases of injured spinal cord repair and describes the construction of an injectable chimeric hydrogel microsphere carrying distinct metal ions with a core-shell structure. Chimeric microspheres overcome the discrepancy between the inflammatory response and neural regeneration and are a promising therapeutic strategy for injured spinal cord repair.

Для цитирования: Liu Xiangyu, Ma Biao, Hu Sihan, Li Dandan, Pan Chun, Xu Zhuobin, Chen Hao, Wang Yongxiang, Wang Huihui. Phase-adapted metal ion supply for spinal cord repair with a Mg-Zn incorporated chimeric microsphere.. Biomaterials. 2025. DOI: 10.1016/j.biomaterials.2025.123253.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.