MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2340/jphs.v61.46484

Медицинская библиотека · Journal of plastic surgery and hand surgery · 2026

In vivo virtual investigation of the implant location for scaphoid fractures.

Xie Ren-Guo, Ji Dong-Shen

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Scaphoid fractures still have high rate of nonunion, mainly due to the tenuous blood supply and only primary bone healing. Rigid fixation facilitates this kind of bone healing and is considered as vital as protection of the blood supply. The optimal implant (screw) location should meet the requirements for researcher's biomechanical findings on fracture stability.

MATERIALS AND

METHODS

Raw CT-scanned data of eight volunteers' wrists were imported into Mimics. The 3D scaphoid was segmented out and calculated, then opened in Geomagic Studio. Four fracture planes (proximal, oblique waist, horizontal waist and distal) simulating common broken scaphoid were created. Mimicking scaphoid implants (screws), the longest, the sub-longest, and central and eccentric cylinders perpendicular to each fracture plane were created. Whole and inside-fragmental length, and the relative location of each cylinder were measured and analyzed.

RESULTS

The longest (28.5 ± 1.6 mm) cylinder was significantly longer than the sub-longest (25.4 ± 1.4 mm). Several eccentric perpendicular cylinders (so short or cutting out of the scaphoid) couldn't be created. Some proximal inside-fragmental lengths ranged from 3.0 to 5.1 mm. Several central perpendicular cylinders intersected with the longest one. Several central and eccentric perpendicular cylinders were outside of the proximal scaphoid non-contact region.

CONCLUSION

The results of this study showed that scaphoid fracture images from CT scan can be calculated and yield the optimal implant location.

Для цитирования: Xie Ren-Guo, Ji Dong-Shen. In vivo virtual investigation of the implant location for scaphoid fractures.. Journal of plastic surgery and hand surgery. 2026. DOI: 10.2340/jphs.v61.46484.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.