Аннотация

Autotitrating continuous positive airway pressure (CPAP) devices automatically adjust the pressure according to upper airway obstructions. The aim of this study was to compare the treatment effects of different automatic CPAP devices (AutoSet, Horizon and Virtuoso) with conventional CPAP in patients with obstructive sleep apnoea independently of financial manufacturer support. Twelve male patients with obstructive sleep apnoea were submitted to a crossover study protocol with overnight polysomnography for 6 consecutive nights. After diagnostic polysomnography, the CPAP pressure was manually titrated. Over the next 4 nights, the patients were treated with any one of the three automatic CPAP devices or fixed CPAP in random order. The apnoea/hypopnoea index on the diagnostic night was 67.3+/-21.7 events h(-1), and was significantly reduced to 0.7+/-1.2, 3.0+/-2.9, 2.3+/-2.5 and 12.0+/-13.6 events x h(-1) with the fixed CPAP, AutoSet, Horizon and Virtuoso devices respectively. An apnoea/ hypopnoea index of <5 events h(-1), an indicator of optimal treatment, was achieved in all patients with fixed CPAP and in 10 patients using the Autoset and Horizon devices, but in only six of the 12 using the Virtuoso. The mean pressure was significantly lower with the AutoSet and Virtuoso devices, but not with the Horizon as compared to fixed CPAP. The maximum pressure was significantly higher with the Horizon. It is concluded that automatic continuous positive airway pressure devices produce a significant reduction in apnoea/hypopnoea index; however, there is considerable difference in the efficacy of the various devices.

Для цитирования: Stammnitz A, Jerrentrup A, Penzel T, Peter J H, Vogelmeier C, Becker H F. Automatic CPAP titration with different self-setting devices in patients with obstructive sleep apnoea.. The European respiratory journal. 2004. DOI: 10.1183/09031936.04.00074304.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.