MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/ac103350y

Медицинская библиотека · Analytical chemistry · 2011

Cell-based quantification of homocysteine utilizing bioluminescent Escherichia coli auxotrophs.

Woo Min-Ah, Kim Moon Il, Yu Byung Jo, Cho Daeyeon, Kim Nag-Jong, Cho June Hyoung, Choi Byung-Ok, Chang Ho Nam, Park Hyun Gyu

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

A cell-based quantitative assay system for Hcy has been developed by utilizing two Escherichia coli auxotrophs that grow in the presence of methionine (Met) and either homocysteine (Hcy) or Met, respectively. A bioluminescent reporter gene, which produces luminescence as cells grow, was inserted into the auxotrophs, so that cell growth can be readily determined. When the relative luminescence unit (RLU) values from the two auxotrophs immobilized within agarose gels arrayed on a well plate were measured, the amount of Hcy was quantitatively determined on the basis of differences between two RLU values corresponding to cell growth of two auxotrophs with excellent levels of precision and reproducibility. Finally, the diagnostic utility of this assay system was verified by its employment in reliably determining different stages of hyperhomocysteinemia in human plasma samples providing CVs of within and between assays that are less than 2.9% and 7.1%, respectively, and recovery rates of within and between assays that are in the range of 99.1-103.5% and 97.5-105.5%, respectively. In contrast to existing conventional methods, the new system developed in this effort is simple, rapid, and cost-effective. As a result, it has great potential to serve as a viable alternative for Hcy quantification in the diagnosis of hyperhomocysteinemia.

Для цитирования: Woo Min-Ah, Kim Moon Il, Yu Byung Jo, Cho Daeyeon, Kim Nag-Jong, Cho June Hyoung, Choi Byung-Ok, Chang Ho Nam, Park Hyun Gyu. Cell-based quantification of homocysteine utilizing bioluminescent Escherichia coli auxotrophs.. Analytical chemistry. 2011. DOI: 10.1021/ac103350y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.