MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1042/cs20040036

Медицинская библиотека · Clinical science (London, England : 1979) · 2004

Heart rate increment: an electrocardiological approach for the early detection of obstructive sleep apnoea/hypopnoea syndrome.

Roche Frédéric, Sforza Emilia, Duverney David, Borderies Jean-René, Pichot Vincent, Bigaignon Odile, Ascher Gilles, Barthélémy Jean-Claude

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

The prevalence of OSAHS (obstructive sleep apnoea/hypopnoea syndrome) is high in developed countries and it is estimated that the vast majority of patients remain undiagnosed. On the basis of physiological evidence, we evaluated the frequency component of HRI (heart rate increment) as a simple and inexpensive screening tool for OSAHS detection in a first group of patients (group 1) and validated their discriminant capacity in a second group (group 2). The predictive accuracy of hourly %VLFI (frequency-domain HRI variable obtained from nocturnal ECG Holter monitoring) was analysed by comparison with an hour-by-hour respiratory disturbances index assessed by complete polysomnography in 28 consecutive clinically suspected OSAHS patients for group 1 and in 35 patients for group 2. OSAHS was present in 20 patients according to a mean hourly apnoea plus hypopnoea index >10 in group 1, and prevalence reached 77.1% in group 2. Sensitivity, specificity and positive and negative predictive accuracy were calculated and an ROC (receiver operating characteristic) curve was constructed for several polysomnographic threshold values. In group 1, hourly %VLFI appeared as an evident predictor of the apnoea/hypopnoea index (W=0.848, P<0.0001; where W is the area under the curve obtained using ROC curve analysis). Using an appropriate threshold (value > or =3.2%), %VLFI demonstrated a sensitivity of 78.1% and a specificity of 70.4%. These thresholds applied to group 2 yielded a sensitivity of 73.9% and a specificity of 76.6%. Frequency-domain analysis of the HRI appears to be a powerful tool for OSAHS prediction. The simplicity of its analysis and use makes of it a particularly well-suited variable for routine mass screening in high-risk populations undergoing ECG Holter monitoring.

Для цитирования: Roche Frédéric, Sforza Emilia, Duverney David, Borderies Jean-René, Pichot Vincent, Bigaignon Odile, Ascher Gilles, Barthélémy Jean-Claude. Heart rate increment: an electrocardiological approach for the early detection of obstructive sleep apnoea/hypopnoea syndrome.. Clinical science (London, England : 1979). 2004. DOI: 10.1042/cs20040036.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.