MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10439-014-0989-5

Медицинская библиотека · Annals of biomedical engineering · 2014

Measurement of ultrasonic attenuation in diabetic neuropathic sciatic nerves for diagnostic and therapeutic applications.

Chen Gin-Shin, Lee Yee-Fun, Cheng Jung-Sung

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Measurements of ultrasonic attenuation in the sciatic nerves of rats were performed to verify the feasibility of ultrasound diagnosis of peripheral neuropathy and to avoid damage to the nerves caused by overheating in pain management applications. A rat model of diabetic peripheral neuropathy was established. The proximal-segment and middle-segment sciatic nerves of control and neuropathic rats were dissected for the attenuation measurement. Two commercial ultrasound transducers and a self-developed experimental platform were used in the measurements. Using H&E staining and transmission electron (TE) microscopy, morphological analysis of the control and neuropathic nerves was performed to determine the relationship between attenuation and the histology of the nerves. The experimental results showed that the attenuation coefficients of the control, second-week, fourth-week, and eighth-week neuropathic nerves were -6.68 ± 0.50, -5.61 ± 0.34, -6.27 ± 0.40, and -7.10 ± 0.35 dB/cm at 2.68 MHz, respectively. The respective values at 7.50 MHz were -14.96 ± 0.79, -12.65 ± 0.28, -13.98 ± 1.07, and -16.00 ± 0.54 dB/cm. The changes in the attenuation coefficients were significantly different among the second-week, fourth-week, and eighth-week DN nerves. Additionally, the ultrasonic attenuation coefficient of the rat sciatic nerve was fourfold that of the cat brain and cow liver and twofold that of human muscle.

Для цитирования: Chen Gin-Shin, Lee Yee-Fun, Cheng Jung-Sung. Measurement of ultrasonic attenuation in diabetic neuropathic sciatic nerves for diagnostic and therapeutic applications.. Annals of biomedical engineering. 2014. DOI: 10.1007/s10439-014-0989-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.