MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/aap.0000000000000056

Медицинская библиотека · Regional anesthesia and pain medicine · 2014

A randomized comparison of the efficacy of 2 techniques for piriformis muscle injection: ultrasound-guided versus nerve stimulator with fluoroscopic guidance.

Fowler Ian M, Tucker Anthony A, Weimerskirch Brian P, Moran Thomas J, Mendez Robert J

Сравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Piriformis muscle injections are most often performed using fluoroscopic guidance; however, ultrasound (US) guidance has recently been described extensively in the literature. No direct comparisons between the 2 techniques have been performed. Our objective was to compare the efficacy and efficiency of fluoroscopic- and US-guided techniques.

METHODS

A randomized, comparative trial was carried out to compare the 2 techniques. Twenty-eight patients with a diagnosis of piriformis syndrome, based on history and physical examination, who had failed conservative treatment were enrolled in the study. Patients were randomized to receive the injection either via US or fluoroscopy. Injections consisted of 10 mL of 1% lidocaine with 80 mg of triamcinalone. The primary outcome measure was numeric pain score, and secondary outcome measures included functional status as measured by the Multidimensional Pain Inventory, patient satisfaction as measured by the Patient Global Impression of Change scale, and procedure timing characteristics. Outcome data were measured preprocedure, immediately postprocedure, and 1 to 2 weeks and 3 months postprocedure.

RESULTS

We found no statistically significant differences in numeric pain scores, patient satisfaction, procedure timing characteristics, or most functional outcomes when comparing the 2 techniques. Statistically significant differences between the 2 techniques were found with respect to the outcome measures of household chores and outdoor work.

CONCLUSIONS

Ultrasound-guided piriformis injections provide similar outcomes to fluoroscopically guided injections without differences in imaging, needling, or overall procedural times.

Для цитирования: Fowler Ian M, Tucker Anthony A, Weimerskirch Brian P, Moran Thomas J, Mendez Robert J. A randomized comparison of the efficacy of 2 techniques for piriformis muscle injection: ultrasound-guided versus nerve stimulator with fluoroscopic guidance.. Regional anesthesia and pain medicine. 2014. DOI: 10.1097/aap.0000000000000056.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.