Advancing HIV Diagnostics: Comparative Evaluation of Multisure HIV-1/2 Rapid Confirmatory Test Against Geenius and Traditional Reference Assays Within a CDC-Aligned Diagnostic Framework.

Ismail Ahmed, Salameh Israa M, Younes Nadin, Nizamuddin Parveen B, Abunasser Shaden, Younes Salma, Abdelmohsen Sara, Abouassali Mazen N, Elshaikh Manal, Karimeh Ibrahim W, Ibrahim Mohammed A, Ali Mutaz M, Al Shaar Ibrahim, Ong Haris, Zhmurov Çiğdem S, Yassine Hadi M, Abu-Raddad Laith J, Ayoub Houssein, Nasrallah Gheyath K

СтатьяПеревод пока не подготовлен

Аннотация

Human immunodeficiency virus (HIV) remains a major global health challenge, requiring accurate diagnostic testing for early detection. Chemiluminescent immunoassay screening, particularly the Architect HIV Ag/Ab Combo assay, followed by immunoblot confirmation using INNO-LIA™ has traditionally been used in many diagnostic workflows. To address these limitations, the U.S. Centers for Disease Control and Prevention (CDC) recommends the use of an HIV-1/2 antibody differentiation immunoassay, such as the Geenius HIV-1/2 Supplemental Assay, as part of the confirmatory testing algorithm. This study evaluates the performance of two rapid HIV-1/2 confirmatory assays-the Multisure HIV-1/2 Confirmatory Test and the Bio-Rad Geenius HIV-1/2 Supplemental Assay-within a CDC-aligned diagnostic framework, with the aim of assessing Multisure as a potential alternative differentiation assay. A total of 224 archived serum samples were analyzed, including true positives (n = 38), true negatives (n = 139), false positives (n = 20), and INNO-LIA™ indeterminate samples (n = 27), as defined by Architect HIV and INNO-LIA™ results. Samples were initially screened using the Architect HIV Ag/Ab Combo assay, confirmed by INNO-LIA™ and PCR, and subsequently re-tested using Multisure HIV-1/2 and Geenius HIV-1/2 assays. Diagnostic performance metrics were evaluated. Both rapid assays demonstrated 100% sensitivity and specificity when compared with INNO-LIA™. Among INNO-LIA™ indeterminate samples, Multisure HIV-1/2 classified 81.5% as negative compared with 55.6% using Geenius HIV-1/2. When compared with PCR, Multisure demonstrated higher specificity (89.2%) and positive predictive value (89.5%) than Geenius (82.9% and 84.6%). No confirmed HIV-2 infections were identified in the analyzed dataset, and HIV-1 subtype information was not available for the archived samples; therefore, conclusions regarding HIV-1/2 differentiation are based primarily on assay design and antigenic targets. Multisure HIV-1/2 demonstrated strong diagnostic performance comparable to established differentiation assays and may represent a practical alternative rapid confirmatory option within CDC-aligned HIV diagnostic workflows. Further studies including larger datasets and confirmed HIV-2 infections are warranted to further validate its clinical utility.

Для цитирования: Ismail Ahmed, Salameh Israa M, Younes Nadin, Nizamuddin Parveen B, Abunasser Shaden, Younes Salma, Abdelmohsen Sara, Abouassali Mazen N, Elshaikh Manal, Karimeh Ibrahim W, Ibrahim Mohammed A, Ali Mutaz M, Al Shaar Ibrahim, Ong Haris, Zhmurov Çiğdem S, Yassine Hadi M, Abu-Raddad Laith J, Ayoub Houssein, Nasrallah Gheyath K. Advancing HIV Diagnostics: Comparative Evaluation of Multisure HIV-1/2 Rapid Confirmatory Test Against Geenius and Traditional Reference Assays Within a CDC-Aligned Diagnostic Framework.. Microorganisms. 2026. DOI: 10.3390/microorganisms14030693.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.