MedElevator Войти в исследования
← Поиск публикаций

DOI 10.25270/jic/26.00071

Медицинская библиотека · The Journal of invasive cardiology · 2026

Impact of ultra-high-pressure OPN NC balloons in complex coronary interventions: indications, safety, and efficacy.

Montilla-Garrido Miguel Ángel, Camacho-Freire Santiago Jesús, Izaga-Torralba Elena, Lluch-Requerey Carmen, Roa-Garrido Jessica, Lagos-De Grande Oscar, Gómez-Menchero Antonio Enrique

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

The OPN super high-pressure noncompliant (NC) balloon (SIS Medical AG) can safely reach inflation pressures of 45 to 50 atm, offering a valuable option for complex coronary interventions. This study aimed to evaluate its safety and efficacy in a real-world setting.

METHODS

The authors conducted an observational, single-center registry including consecutive patients treated with the OPN balloon over 13 years. Procedural indication, safety, and efficacy were assessed using quantitative coronary angiography (QCA). Major adverse cardiovascular events (MACE)-defined as cardiovascular death, myocardial infarction, or target lesion revascularization-were analyzed at 1-year follow-up.

RESULTS

A total of 275 patients (289 lesions) were included. The cohort was highly complex (mean age 70 ± 10 years, 66% multivessel disease, 66% diabetes, 35% in-stent restenosis [ISR]). The main indication was plaque preparation (68%), followed by stent optimization (32%). Procedural success was 95%, with one-third of lesions requiring inflation pressures of greater than or equal to 40 atm. QCA demonstrated a significant increase in minimal lumen diameter (1.31 ± 0.66 mm to 2.13 ± 0.62 mm, P < .001) and a reduction in diameter stenosis (51% to 24%, P < 0.001). Safety outcomes were excellent, with very low complication rates. At 1 year, MACE occurred in 3.8% of patients (stent thrombosis 0.7%). Outcomes were similar between de novo and ISR lesions. Diabetes and chronic kidney disease independently predicted MACE.

CONCLUSIONS

In routine clinical practice, the OPN NC balloon demonstrated high efficacy and an excellent safety profile, achieving significant luminal gain at ultra-high pressures. These findings support its role for lesion preparation and stent optimization.

Для цитирования: Montilla-Garrido Miguel Ángel, Camacho-Freire Santiago Jesús, Izaga-Torralba Elena, Lluch-Requerey Carmen, Roa-Garrido Jessica, Lagos-De Grande Oscar, Gómez-Menchero Antonio Enrique. Impact of ultra-high-pressure OPN NC balloons in complex coronary interventions: indications, safety, and efficacy.. The Journal of invasive cardiology. 2026. DOI: 10.25270/jic/26.00071.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.