MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12903-025-06242-5

Медицинская библиотека · BMC oral health · 2025

Evaluation of symphysis donor site quantity by cone-beam computed tomography and its relation to anterior loop of mental foramen: an observational study.

Cimen Tansu, Saka Yunus Yigit, Ataman-Duruel Emel Tuğba, Duruel Onurcem, Güney Yilmaz Hasan, Tözüm Tolga Fikret

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

For severely atrophic alveolar ridges, block grafting procedures are usually decided to use for reliable results. Various intraoral donor sites for autogenous block graft are presented in the literature. However, vital anatomic structures can limit intraoral bone block graft surgeries, and they must be evaluated in detail. The aim of this study is to evaluate the dimensions and volume of the maximum potential symphysis block graft donor site and their relations to the anterior loop of mental foramen.

MATERIALS AND

METHODS

According to inclusion criteria, 408 cone beam computed tomography (CBCT) images were evaluated. Mental foramen diameter, anterior loop length, the maximum potential symphysis graft dimensions (height, width, and length) and volume were measured.

RESULTS

Prevalence of anterior loop of mental foramen was calculated 30.15% (123 patients) for right and 29.66% (121 patients) for left sides. The length of anterior loop of mental foramen was measured for right and left side 4.470 ± 1.355 and 5.223 ± 1.599, respectively. The maximum potential symphysis graft height, width, length, and volume were 13.253 ± 3.261 mm, 12.694 ± 1.711 mm, 34.353 ± 2.944 mm, and 3.102 ± 1.013 cm 3, respectively. Presenting anterior loop has no significant effect on the maximum potential symphysis graft height (P = 0.560) and width (P = 0.242). However, the maximum potential symphysis block graft length (P = 0.017) and volume (P = 0.026) were decreased by increasing number of anterior loops of mental foramen.

CONCLUSION

The mandibular symphysis bone block graft can be reliably selected as the donor site for a number of different augmentation procedures. However, there are restrictions owing to surrounding anatomical structures such as mental foramen and anterior loop. These vital structures should be considered using accurate CBCT evaluation. Presenting anterior loop of mental foramen is limiting symphysis bone block graft length and volume.

Для цитирования: Cimen Tansu, Saka Yunus Yigit, Ataman-Duruel Emel Tuğba, Duruel Onurcem, Güney Yilmaz Hasan, Tözüm Tolga Fikret. Evaluation of symphysis donor site quantity by cone-beam computed tomography and its relation to anterior loop of mental foramen: an observational study.. BMC oral health. 2025. DOI: 10.1186/s12903-025-06242-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.