MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/cmtr18010007

Медицинская библиотека · Craniomaxillofacial trauma & reconstruction · 2025

Proportional Condylectomy Using a Titanium 3D-Printed Cutting Guide in Patients with Condylar Hyperplasia.

Smolka Wenko, Cornelius Carl-Peter, Obermeier Katharina Theresa, Otto Sven, Liokatis Paris

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The purpose of the study was to describe proportional condylectomy in patients with condylar hyperplasia using a titanium 3D-printed ultrathin wire mesh cutting guide placed below the planned bone resection.

METHODS

Eight patients with condylar hyperplasia underwent proportional condylectomy using an ultrathin titanium 3D-printed cutting guide placed below the planned bone resection. The placement of the guide was facilitated by the incorporation of anatomical landmarks. The accuracy of bone resections guided by such devices was evaluated on postoperative radiographs. The mean postoperative follow-up was 30 months.

RESULTS

Surgery could be performed in all patients in the same manner as virtually planned. The fitting accuracy of the cutting guides was judged as good. Postoperative radiographs revealed that the virtually planned shape of the newly formed condylar head after condylectomy could be achieved.

CONCLUSIONS

In conclusion, the use of virtual computer-assisted planning and CAD/CAM-based cutting guides for proportional condylectomy in unilateral condylar hyperplasia of the mandible offers high accuracy and guarantees very predictable results.

Для цитирования: Smolka Wenko, Cornelius Carl-Peter, Obermeier Katharina Theresa, Otto Sven, Liokatis Paris. Proportional Condylectomy Using a Titanium 3D-Printed Cutting Guide in Patients with Condylar Hyperplasia.. Craniomaxillofacial trauma & reconstruction. 2025. DOI: 10.3390/cmtr18010007.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.