DOI 10.1016/j.jtcvs.2014.06.070
Results of type II hybrid arch repair with zone 0 stent graft deployment for complex aortic arch pathology.
Аннотация
OBJECTIVE
To review the early results of a less invasive, single-stage hybrid arch procedure involving replacement of the ascending aorta, arch debranching, and zone 0 antegrade stent graft deployment.
METHODS
Between May 2007 and January 2012, 20 patients with both acute and chronic aortic pathology were managed at 2 institutions with a type 2 hybrid arch procedure. Indications included diffuse atherosclerotic aneurysm, false lumen expansion of chronic aortic dissections, penetrating atherosclerotic ulcer, and acute type A dissection. Mean age was 67 ± 16.8 years with a mean European System for Cardiac Operative Risk Evaluation II score of 29.5 ± 19.4. Postoperative clinical and imaging follow-up was complete to a mean 18.5 ± 15.3 months.
RESULTS
Successful zone 0 stent graft deployment was achieved in all cases. There was 1 in-hospital mortality (5%). A second death occurred at 40 days postoperation. Other complications included a permanent neurologic deficit in 1 patient (5%), transient paraplegia in 4 patients (20%), and 3 patients had respiratory complications (15%). There were no cases of renal failure requiring dialysis. Stent-related complications were identified in 4 patients (20%), including 3 type I endoleaks, none of which were at zone 0. There was 1 type II endoleak and a case of stent infolding. Two patients required a second successful endografting procedure.
CONCLUSIONS
This single-stage hybrid arch procedure offers an alternative approach to complex diffuse aortic pathology involving the arch. Replacement of the ascending aorta provides a safe location for zone 0 stent graft deployment, eliminating complications of proximal deployment in a native diseased aorta.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.