Custom-made versus off-the-shelf multibranched endografts for endovascular repair of thoracoabdominal aortic aneurysms.
Аннотация
OBJECTIVE
This study compared early outcomes between the custom-made and the new off-the-shelf multibranched endograft (mbEVAR, t-branch; Cook Medical, Bloomington, Ind) for the endovascular repair of thoracoabdominal aortic aneurysms (TAAAs).
METHODS
Between January 2010 and January 2013, 46 consecutive patients with TAAAs underwent endovascular aortic repair with mbEVARs. A custom-made device was used in 24 patients (group A, 52%), with Crawford classification type I, 2 (8%); type II, 4 (17%); type III, 9 (38%); and type IV/V, 9 (38%), and the a t-branch endograft was used in 22 patients (group B, 47%), with type II, 9 (41%); type III, 12 (55%); and type IV/V, 1 (4%). The main outcome measure was technical success, defined as successful target revascularization without occlusion of the bridging endografts or type I or III endoleak at the completion angiography. Secondary end points were mortality, unplanned reinterventions, branch occlusion, paraplegia, and persistent (after discharge) paraparesis.
RESULTS
Technical success was 100% in both groups. The 30-day mortality was 8% in group A (n = 2) and 0% in group B (P = .51). Survival rates at 6 months were 71% in group A (mean follow-up, 13 ± 11 months) and 94% in group B (mean follow-up, 6 ± 3 months; (P = .04). There was only one procedure-related death caused by cerebral bleeding and herniation in group A. The freedom-from-reintervention rate at 6 months was 100% in group A (mean follow-up, 12 ± 11.5 months) and 90% in group B (mean follow-up, 6 ± 3.9 months; P = .07). No branch occlusions were observed in group A, whereas a branch occlusion occurred in three patients in group B (in all cases the bridging endograft for the renal artery). In two patients, the possible reason for branch occlusion was a thrombophilic disorder, whereas in one patient, the reason remains unknown. Paraplegia was observed in one patient in each group (group A: 4%; group B: 5%; P = .51) and persistent paraparesis in two patients in group A (8%) and in one patient (5%) in group B (P = .94).
CONCLUSIONS
The t-branch device, with the unique advantage of direct implantation without any delay for manufacturing, showed 100% technical success and comparable clinical outcomes to the traditional custom-made mbEVARs. Further long-term evaluation remains mandatory.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.