Diabetes care · 2020
Differences in Physiological Responses to Cardiopulmonary Exercise Testing in Adults With and Without Type 1 Diabetes: A Pooled Analysis.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Eckstein Max L, Farinha Juliano Boufleur, McCarthy Olivia, West Daniel J, Yardley Jane E, Bally Lia, Zueger Thomas, Stettler Christoph, Boff Winston, Reischak-Oliveira Alvaro, Riddell Michael C, Zaharieva Dessi P, Pieber Thomas R, Müller Alexander, Birnbaumer Philipp, Aziz Faisal, Brugnara Laura, Haahr Hanne, Zijlstra Eric, Heise Tim, Sourij Harald, Roden Michael, Hofmann Peter, Bracken Richard M, Pesta Dominik, Moser Othmar
Аннотация
OBJECTIVE: To investigate physiological responses to cardiopulmonary exercise (CPX) testing in adults with type 1 diabetes compared with age-, sex-, and BMI-matched control participants without type 1 diabetes.
RESEARCH DESIGN AND METHODS: We compared results from CPX tests on a cycle ergometer in individuals with type 1 diabetes and control participants without type 1 diabetes. Parameters were peak and threshold variables of VO2, heart rate, and power output. Differences between groups were investigated through restricted maximum likelihood modeling and post hoc tests. Differences between groups were explained by stepwise linear regressions (P < 0.05).
RESULTS: Among 303 individuals with type 1 diabetes (age 33 [interquartile range 22; 43] years, 93 females, BMI 23.6 [22; 26] kg/m2, HbA1c 6.9% [6.2; 7.7%] [52 (44; 61) mmol/mol]), VO2peak (32.55 [26.49; 38.72] vs. 42.67 ± 10.44 mL/kg/min), peak heart rate (179 [170; 187] vs. 184 [175; 191] beats/min), and peak power (216 [171; 253] vs. 245 [200; 300] W) were lower compared with 308 control participants without type 1 diabetes (all P < 0.001). Individuals with type 1 diabetes displayed an impaired degree and direction of the heart rate-to-performance curve compared with control participants without type 1 diabetes (0.07 [-0.75; 1.09] vs. 0.66 [-0.28; 1.45]; P < 0.001). None of the exercise physiological responses were associated with HbA1c in individuals with type 1 diabetes.
CONCLUSIONS: Individuals with type 1 diabetes show altered responses to CPX testing, which cannot be explained by HbA1c. Intriguingly, the participants in our cohort were people with recent-onset type 1 diabetes; heart rate dynamics were altered during CPX testing.
RESEARCH DESIGN AND METHODS: We compared results from CPX tests on a cycle ergometer in individuals with type 1 diabetes and control participants without type 1 diabetes. Parameters were peak and threshold variables of VO2, heart rate, and power output. Differences between groups were investigated through restricted maximum likelihood modeling and post hoc tests. Differences between groups were explained by stepwise linear regressions (P < 0.05).
RESULTS: Among 303 individuals with type 1 diabetes (age 33 [interquartile range 22; 43] years, 93 females, BMI 23.6 [22; 26] kg/m2, HbA1c 6.9% [6.2; 7.7%] [52 (44; 61) mmol/mol]), VO2peak (32.55 [26.49; 38.72] vs. 42.67 ± 10.44 mL/kg/min), peak heart rate (179 [170; 187] vs. 184 [175; 191] beats/min), and peak power (216 [171; 253] vs. 245 [200; 300] W) were lower compared with 308 control participants without type 1 diabetes (all P < 0.001). Individuals with type 1 diabetes displayed an impaired degree and direction of the heart rate-to-performance curve compared with control participants without type 1 diabetes (0.07 [-0.75; 1.09] vs. 0.66 [-0.28; 1.45]; P < 0.001). None of the exercise physiological responses were associated with HbA1c in individuals with type 1 diabetes.
CONCLUSIONS: Individuals with type 1 diabetes show altered responses to CPX testing, which cannot be explained by HbA1c. Intriguingly, the participants in our cohort were people with recent-onset type 1 diabetes; heart rate dynamics were altered during CPX testing.