Interventricular mechanical dyssynchrony: quantification with velocity-encoded MR imaging.

Muellerleile Kai, Baholli Loant, Groth Michael, Barmeyer Achim A, Koopmann Katharina, Ventura Rodolfo, Koester Ralf, Adam Gerhard, Willems Stephan, Lund Gunnar K

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the performance of velocity-encoded (VENC) magnetic resonance (MR) imaging, as compared with pulsed-wave echocardiography (PW-ECHO), in the quantification of interventricular mechanical dyssynchrony (IVMD) as a predictor of response to cardiac resynchronization therapy (CRT).

MATERIALS AND

METHODS

The study was approved by the local ethics committee, and all patients provided written informed consent. The study involved the examination of 45 patients (nine women, 36 men; median age, 60 years; interquartile age range, 47-69 years) with New York Heart Association class 2.0-3.0 heart failure and a reduced left ventricular ejection fraction (median, 25%; interquartile range, 21%-32%), with (n = 25) or without (n = 20) left bundle branch block. Aortic and pulmonary flow curves were constructed by using VENC MR imaging and PW-ECHO. IVMD was defined as the difference between the onset of aortic flow and the onset of pulmonary flow. Intraclass correlation coefficient, Spearman correlation coefficient, Bland-Altman, and Cohen kappa analyses were used to assess agreement between observers and methods.

RESULTS

Inter- and intraobserver agreement regarding VENC MR imaging IVMD measurements was very good (intraclass r = 0.96, P < .001; mean bias, -3 msec +/- 11 [standard deviation] and 0 msec +/- 10, respectively). A strong correlation (Spearman r = 0.92, P < .001) and strong agreement (mean difference, -6 msec +/- 16) were found between VENC MR imaging and PW-ECHO in the quantification of IVMD. Agreement between VENC MR imaging and PW-ECHO in the identification of potential responders to CRT was excellent (Cohen kappa = 0.94).

CONCLUSION

VENC MR measurements of IVMD are equivalent to PW-ECHO measurements and can be used to identify potential responders to CRT.

Для цитирования: Muellerleile Kai, Baholli Loant, Groth Michael, Barmeyer Achim A, Koopmann Katharina, Ventura Rodolfo, Koester Ralf, Adam Gerhard, Willems Stephan, Lund Gunnar K. Interventricular mechanical dyssynchrony: quantification with velocity-encoded MR imaging.. Radiology. 2009. DOI: 10.1148/radiol.2532090145.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.