MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/17434440.2022.2077642

Медицинская библиотека · Expert review of medical devices · 2022

Diagnostic accuracy of liver stiffness on two-dimensional shear wave elastography for detecting clinically significant portal hypertension: a meta-analysis.

Dong Bingtian, Chen Yuping, Chen Yongjian, Wang Huaming, Lyu Guorong

МетаанализСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Two-dimensional shear wave elastography (2D-SWE) has recently been proposed to detect clinically significant portal hypertension (CSPH), we aimed to perform a meta-analysis based on the published data to assess the diagnostic accuracy of 2D-SWE for detecting CSPH.

METHOD: Literature databases were searched up until 1 August 2021. The summary area under receiver operating characteristics curve (AUROC), the summary diagnostic odds ratio (DOR), and the summary sensitivity and specificity were used to examine the accuracy of 2D-SWE for evaluating CSPH. Heterogeneity was explored using meta-regression.

RESULTS

Finally 9 studies with 956 patients were included in this study for evaluation and meta-analysis. 2D-SWE showed good diagnostic performance for detecting CSPH with a summary sensitivity of 83% (95% confidence interval [CI]: 76%-88%) and summary specificity of 78% (95% CI: 65%-87%); the summary AUROC was 0.88 (95% CI: 0.84-0.90). Summary positive likelihood ratio (LR), negative LR, and DOR of 2D-SWE for detecting CSPH were 3.7 (95% CI: 2.4-5.9), 0.22 (95% CI: 0.16-0.30), and 17 (95% CI: 10-29), respectively.

CONCLUSIONS

2D-SWE showed good performance in diagnosing CSPH and can be considered as an important and noninvasive adjunctive approach in the management of patients with CSPH.

Для цитирования: Dong Bingtian, Chen Yuping, Chen Yongjian, Wang Huaming, Lyu Guorong. Diagnostic accuracy of liver stiffness on two-dimensional shear wave elastography for detecting clinically significant portal hypertension: a meta-analysis.. Expert review of medical devices. 2022. DOI: 10.1080/17434440.2022.2077642.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.