Characterization of mesenteric and portal hemodynamics using 4D flow MRI: the effects of meals and diurnal variation.

Roldán-Alzate Alejandro, Campo Camilo A, Mao Lu, Said Adnan, Wieben Oliver, Reeder Scott B

СтатьяПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

PURPOSE: To determine the variability of blood flow measurements using 4D flow MRI in the portal and mesenteric circulations and to characterize the effects of meal ingestion, time of day, and between-day (diurnal) variations on portal and mesenteric hemodynamics.

METHODS

In this IRB-approved and HIPAA-compliant study, 7 healthy and 7 portal hypertension patients imaged. MRI exams were conducted at 3 T using a 32-channel body coil with large volumetric coverage and 1.25-mm isotropic true spatial resolution. Blood flow was quantified (L/min) in the hepatic and splanchnic vasculature. The first MR scan was performed after at least 8 h of fasting. Subsequently, subjects ingested 574 mL EnSure Plus® orally. A second acquisition was started 20 min after the meal ingestion. A third scan was performed before lunch and a fourth acquisition took place 20 min after lunch. A fifth scan was performed around 4 pm. Finally, subjects returned one week later for a repeat morning visit, with identical conditions as the first visit.

RESULTS

In healthy controls significant increase in blood flow was seen in the PV, SMV, SMA, HA, and SCAo in response to breakfast but only the SCAo, SMA, SMV, and PV had a significant response to lunch. In general, patients with cirrhosis showed reduced response to meals compared to that in healthy controls. Additionally, PV flow in patients had the highest value in the afternoon.

CONCLUSION

Effects of meal ingestion, time of day, and between-day variations were characterized using Radial 4D flow MRI in patients with cirrhosis and healthy controls.

Для цитирования: Roldán-Alzate Alejandro, Campo Camilo A, Mao Lu, Said Adnan, Wieben Oliver, Reeder Scott B. Characterization of mesenteric and portal hemodynamics using 4D flow MRI: the effects of meals and diurnal variation.. Abdominal radiology (New York). 2022. DOI: 10.1007/s00261-022-03513-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.