m+Medelevator.RU
← Поиск публикаций
Clinica chimica acta; international journal of clinical chemistry · 2005

Risk stratification of chest pain patients by point-of-care cardiac troponin T and myoglobin measured in the emergency department.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ordóñez-Llanos Jordi, Santaló-Bel Miquel, Mercé-Muntañola Javier, Collinson Paul O, Gaze David, Haass Markus, Katus Hugo A, Chwallek Frank, Hirschl Michael M, Derhaschnig Ulla, Mueller-Bardorff Margit, Kellett John, Sylvén Christer, Schulz Ilse, Zerback Rainer, CARMYT Multicentre Study Group

Аннотация

A prospective multicenter study including 1410 chest pain patients with suspected acute coronary syndromes was carried out to examine the predictive value of biological cardiac markers for adverse events measured by a point-of-care system. Admission cardiac troponin T (cTnT) and myoglobin were measured in parallel on a point-of-care system in the emergency department and -- together with CK-MB mass -- on lab analyzers. In a one-year follow-up, cardiac and non-cardiac death, acute myocardial infarction, unstable angina pectoris and need for revascularization were registered. Median time between onset of symptoms and admission was 285 min; 172 patients (12.2%) had no event during follow-up. If the cTnT, measured either by the point-of-care system or a conventional lab analyzer, was >0.05 microg/L, then the chance of a cardiac event during the follow-up period was doubled (18% vs. 9%). Serial cTnT measurement did not add any further value to the predictive power of the admission cTnT. Myoglobin and CK-MB mass identified increasing risk with increasing concentration quartiles; cardiac event rates were 2.8- to 4.4-fold higher between the quartiles with the lowest and those with the highest analyte concentration, respectively. There was no difference in non-cardiac death rates between any concentration quartiles. In conclusion, the prediction of clinical events by cardiac troponin T and myoglobin measured with a point-of-care analyzer in the emergency department was as good as that of the same cardiac markers and CK-MB mass measured on lab analyzers.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты