Serum concentrations of high-sensitivity C-reactive protein predict progressively obstructive lesions rather than late restenosis in patients with unstable angina undergoing coronary artery stenting.
Аннотация
BACKGROUND
The present study tested the hypothesis that high-sensitivity C-reactive protein (hs-CRP) concentrations might show significant serial changes in patients with unstable angina (UAP), and that elevation of hs-CRP might indicate a progressively obstructive lesion, rather than late restenosis in such patients undergoing coronary stenting.
METHODS AND
RESULTS
Serum concentrations of hs-CRP in 168 patients with UAP undergoing coronary stenting for a new obstructive lesion were prospectively measured (pre-procedure, and on days 21, 90, and 180 post-procedure). The hs-CRP concentrations were also evaluated in 30 at-risk controls and 50 healthy volunteers. Moderately obstructive lesions of non-culprit vessels (defined as > or =50-69% stenosis) that were not treated by coronary angioplasty were found in 107 (63.7%) patients. The hs-CRP concentration was significantly higher at pre-procedure in the study patients than in the controls and healthy volunteers (all p-values <0.0001) and markedly declined after the procedure (p<0.0001). Pre-procedure (p=0.799) and post-procedure hs-CRP concentrations (all p-values >0.1) did not differ between restenotic and non-restenotic patients. However, at pre-procedure or on day 180, the concentration of hs-CRP was independently associated with progressively obstructive lesions of non-culprit vessels that required coronary angioplasty (both p-values <0.05).
CONCLUSION
The hs-CRP concentration was significantly higher at pre-procedure and declined substantially thereafter in patients with UAP following coronary stenting. There was no evidence of a positive association between an elevated hs-CRP concentration and late restenosis. However, both the pre-procedure and day 180 concentrations of hs-CRP were strongly associated with the progression of moderately obstructive lesions in non-culprit vessels.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.