MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10439-017-1885-6

Медицинская библиотека · Annals of biomedical engineering · 2017

Modelling of Lesions Associated with Functional Mitral Regurgitation in an Ex Vivo Platform.

Jaworek Michal, Lucherini Federico, Romagnoni Claudia, Gelpi Guido, Contino Monica, Romitelli Paolo, Antona Carlo, Fiore Gianfranco B, Vismara Riccardo

СтатьяПеревод пока не подготовлен

Аннотация

Functional mitral regurgitation (FMR) is a complex pathology involving valvular and subvalvular structures reconfiguration, and its treatment is considered challenging. There is a lack of experimental models allowing for reliable preclinical FMR treatments' evaluation in a realistic setting. A novel approach to simulate FMR was developed and incorporated into an ex vivo passive beating heart platform. FMR was obtained by dilating the mitral annulus (MA) mainly in the antero-posterior direction and displacing the papillary muscles (PMs) apically and laterally by ad hoc designed and 3D printed dilation and displacing devices. It caused hemodynamic and valve morphology alterations. Isolated MA dilation (MAD) led to significantly increased antero-posterior distance (A-P) and decreased coaptation height (CH), tenting area (TA) and systolic leaflets angulation, resembling clinically recognized type I of mitral regurgitation with normal leaflet motion. Whereas concomitant MAD with PM displacement caused an increase in A-P, TA, CH. This geometrical configuration replicated typical determinants of type IIIb lesion with restricted leaflet motion. The proposed methods provided a realistic and repeatable ex vivo FMR model featuring two lesions clinically associated with the pathology. It bears a promise to be successfully utilized in preclinical studies, clinical training and medical education.

Для цитирования: Jaworek Michal, Lucherini Federico, Romagnoni Claudia, Gelpi Guido, Contino Monica, Romitelli Paolo, Antona Carlo, Fiore Gianfranco B, Vismara Riccardo. Modelling of Lesions Associated with Functional Mitral Regurgitation in an Ex Vivo Platform.. Annals of biomedical engineering. 2017. DOI: 10.1007/s10439-017-1885-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.