International journal of cardiology · 2017
Immediate increase of cardiac output after percutaneous mitral valve repair (PMVR) determined by echocardiographic and invasive parameters: Patzelt: Increase of cardiac output after PMVR.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Patzelt Johannes, Zhang Yingying, Magunia Harry, Jorbenadze Rezo, Droppa Michal, Ulrich Miriam, Cai Shanglang, Lausberg Henning, Walker Tobias, Wengenmayer Tobias, Rosenberger Peter, Schreieck Juergen, Seizer Peter, Gawaz Meinrad, Langer Harald F
Аннотация
BACKGROUND: Successful percutaneous mitral valve repair (PMVR) in patients with severe mitral regurgitation (MR) causes changes in hemodynamics. Echocardiographic calculation of cardiac output (CO) has not been evaluated in the setting of PMVR, so far. Here we evaluated hemodynamics before and after PMVR with the MitraClip system using pulmonary artery catheterization, transthoracic (TTE) and transesophageal (TEE) echocardiography.
METHODS: 101 patients with severe MR not eligible for conventional surgery underwent PMVR. Hemodynamic parameters were determined during and after the intervention. We evaluated changes in CO and pulmonary artery systolic pressure before and after PMVR. CO was determined with invasive parameters using the Fick method (COi) and by a combination of TTE and TEE (COe).
RESULTS: All patients had successful clip implantation, which was associated with increased COi (from 4.6±1.4l/min to 5.4±1.6l/min, p<0.001). Furthermore, pulmonary artery systolic pressure (PASP) showed a significant decrease after PMVR (47.6±16.1 before, 44.7±15.5mmHg after, p=0.01). In accordance with invasive measurements, COe increased significantly (COe from 4.3±1.7l/min to 4.8±1.7l/min, p=0.003). Comparing both methods to calculate CO, we observed good agreement between COi and COe using Bland Altman plots.
CONCLUSIONS: CO increased significantly after PMVR as determined by echocardiography based and invasive calculation of hemodynamics during PMVR. COe shows good agreement with COi before and after the intervention and, thus, represents a potential non-invasive method to determine CO in patients with MR not accessible by conventional surgery.
METHODS: 101 patients with severe MR not eligible for conventional surgery underwent PMVR. Hemodynamic parameters were determined during and after the intervention. We evaluated changes in CO and pulmonary artery systolic pressure before and after PMVR. CO was determined with invasive parameters using the Fick method (COi) and by a combination of TTE and TEE (COe).
RESULTS: All patients had successful clip implantation, which was associated with increased COi (from 4.6±1.4l/min to 5.4±1.6l/min, p<0.001). Furthermore, pulmonary artery systolic pressure (PASP) showed a significant decrease after PMVR (47.6±16.1 before, 44.7±15.5mmHg after, p=0.01). In accordance with invasive measurements, COe increased significantly (COe from 4.3±1.7l/min to 4.8±1.7l/min, p=0.003). Comparing both methods to calculate CO, we observed good agreement between COi and COe using Bland Altman plots.
CONCLUSIONS: CO increased significantly after PMVR as determined by echocardiography based and invasive calculation of hemodynamics during PMVR. COe shows good agreement with COi before and after the intervention and, thus, represents a potential non-invasive method to determine CO in patients with MR not accessible by conventional surgery.