MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.apradiso.2023.111124

Медицинская библиотека · Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2023

Evaluating dose distributions of high dose rate 60Co brachytherapy in an asymmetric tumor: A comparison of different designs of vaginal cylindrical applicators.

Aloraibi Hayder Adil, Siavashpour Zahra, Ghorbani Mahdi, Abtahi Marzieh, Jassim Hussam, Gholami Somayeh

СтатьяПеревод пока не подготовлен

Аннотация

The aim of this study is to evaluate organ-at-risk (OAR) doses obtained from different designs of intracavitary cylinder applicators during high-dose-rate (HDR) brachytherapy of an asymmetric vaginal tumor. Dose distributions around five cylinder applicators were obtained using the Geant4 toolkit. Three of these applicators are commercially available: single-channel, multi-channel, and shielded. Additionally, two proposed sub-configurations were evaluated: (I) a combination of the multichannel applicator with a central shield and (II) a dynamically modulated cylinder (DMC). The dose distributions of the proposed applicators were compared to those of the single-channel cylinder applicator. The results showed that using a cylindrical applicator with a higher degree of freedom in plan optimization can improve OAR, sparing up to 60% for the rectum and 20% for the bladder. In conclusion, this work suggests using a new design of a cylindrical applicator to enhance the therapeutic ratio of brachytherapy for asymmetric and irregularly shaped vaginal tumors.

Для цитирования: Aloraibi Hayder Adil, Siavashpour Zahra, Ghorbani Mahdi, Abtahi Marzieh, Jassim Hussam, Gholami Somayeh. Evaluating dose distributions of high dose rate 60Co brachytherapy in an asymmetric tumor: A comparison of different designs of vaginal cylindrical applicators.. Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine. 2023. DOI: 10.1016/j.apradiso.2023.111124.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.