MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.radonc.2023.109909

Медицинская библиотека · Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2023

Are 7.5 Gy×2 fractions more efficient than 6 Gy×3 in exclusive postoperative endometrial cancer brachytherapy? A clinical and dosimetrical analysis.

Noorian Faegheh, Abellana Rosa, Zhang Yaowen, Herreros Antonio, Baltrons Clara, Lancellota Vallentina, Tagliaferri Luca, Sabater Sebastia, Torne Aureli, Rovirosa Angeles

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare two vaginal brachytherapy (VBT) schedules in postoperative endometrial carcinoma (PEC) patients considering vaginal-cuff relapses (VCR), late toxicities, dosimetry analysis and vaginal dilator use.

MATERIAL AND

METHODS

110 PEC patients were treated with exclusive high-dose-rate VBT using two schedules. Group-1:44-patients received 6 Gy×3fractions (September-2011-April-2014); Group-2:66-patients were treated with 7.5 Gy×2fractions with a dose limit of equivalent total doses in 2-Gy fr (EQD2(α/β=3)) of 68 Gy in the most exposed 2 cm3 of clinical target volume (CTV) (July-2015-November-2021). The dose was prescribed at 5 mm from the applicator surface. Were evaluated the overall radiation dose delivered to 90% of the CTV (D90), the CTV receiving 100% of the prescription dose (V100) and the EQD2(α/β=3) received in the most exposed 2 cm3 to dose in CTV. Late toxicity was prospectively assessed using RTOG scores for bladder and rectum and objective LENT-SOMA criteria for late vaginal toxicity (LVT).

STATISTICS: Descriptive analysis, Chi-square, Student's t-tests and Kaplan and Meier method.

RESULTS

The median follow-up was 60 months (15.9-60). There were no VCR or late toxicities in bladder or rectum. LVT ≥ G1 appeared in 26/44 (59.1%) in Group-1 and 25/66 (37.9%) in Group-2. The mean EQD2(α/β=3) received by the most exposed 2 cm3 of CTV was 63.7 Gy ± 10.0 in Group-1 and 60.5 Gy ± 3.8 in Group-2 (p = 0.063). There were no differences in adherence to vaginal dilator use ≥9 months, overall D90 and V100.

CONCLUSION

Considering the lack of vaginal relapses and similar LVT over time, 7.5 Gy×2fractions seem more efficient in terms of patient comfort, workload, and cost. This is the first study using dosimetry parameters to compare effectivity of schedules. Larger series are needed to confirm the present results.

Для цитирования: Noorian Faegheh, Abellana Rosa, Zhang Yaowen, Herreros Antonio, Baltrons Clara, Lancellota Vallentina, Tagliaferri Luca, Sabater Sebastia, Torne Aureli, Rovirosa Angeles. Are 7.5 Gy×2 fractions more efficient than 6 Gy×3 in exclusive postoperative endometrial cancer brachytherapy? A clinical and dosimetrical analysis.. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. 2023. DOI: 10.1016/j.radonc.2023.109909.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.