MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1227/ons.0000000000001950

Медицинская библиотека · Operative neurosurgery (Hagerstown, Md.) · 2026

Robot-Assisted Placement of Convection-Enhanced Delivery Infusion Cannulas.

Damante Mark A, Elder J Bradley, Everson Richard G, Chen H Isaac, Harmelink Matthew, Lee Jun, Lonser Russell R

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVES

Indications for convective delivery of putative therapeutics are rapidly expanding. Cerebellar targets, such as the dentate nucleus, will be crucial to target in certain conditions. Current skull-mounted, magnetic resonance (MR) imaging-compatible platforms preclude infratentorial approach to cerebellar targets. We assessed the feasibility, effectiveness, and accuracy of computed tomography (CT) and MR imaging guided, robot-assisted placement of convection enhanced delivery (CED) cannulas.

METHODS

Cadaveric (n = 5) specimens underwent preoperative CT and MR-imaging for trajectory and target (bilateral dentate nuclei) planning followed by robot-assisted placement of suboccipital cannulas (n = 10). Placement accuracy was assessed using CT and MR-imaging.

RESULTS

All cadaveric (3 female, 2 male) specimens underwent successful suboccipital placement of bilateral CED cannulas to the dentate nuclei along defined trajectories. Mean incision to cannula placement time was 22 ± 0.6 minutes (range, 13-35 minutes). Medial-lateral error was 1.2 ± 1.1 mm (range, 0.1-3.6 mm), rostral-caudal error was 1.0 ± 0.6 mm (range, 0.1-2.1 mm), and depth error was 0.7 ± 0.4 mm (range, 0.2-1.5 mm) on CT. Mean medial-lateral error was 1.4 ± 0.9 mm (range, 0.1-2.8 mm), rostral-caudal error was 0.9 ± 0.5 mm (range, 0.3-1.8 mm), and depth error was 0.9 ± 0.6 mm (range, 0.1-2.0 mm) on MR imaging. CT accuracy errors were analogous to MR imaging errors (t-test, P ≥ .3).

CONCLUSION

Image-guided, robot-assisted placement of CED cannulas is feasible, accurate, and efficient. This paradigm can provide advantages in placing convective infusion cannulas compared with existing methods.

Для цитирования: Damante Mark A, Elder J Bradley, Everson Richard G, Chen H Isaac, Harmelink Matthew, Lee Jun, Lonser Russell R. Robot-Assisted Placement of Convection-Enhanced Delivery Infusion Cannulas.. Operative neurosurgery (Hagerstown, Md.). 2026. DOI: 10.1227/ons.0000000000001950.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.