MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clinimag.2021.04.025

Медицинская библиотека · Clinical imaging · 2021

Quantifying magnetic resonance imaging features to classify placenta accreta spectrum (PAS) in high-risk gravid patients.

Chu Caiting, Liu Ming, Zhang Yuzheng, Yu Lingwei, Wang Dengbin, Gao Chengjin, Li Wenhua

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

This study aimed to quantify the magnetic resonance imaging (MRI) features of placenta accreta spectrum (PAS) and to use MRI-based scores to classify them in high-risk gravid patients.

MATERIALS AND

METHODS

The clinical data and MRI features of 65 high-risk gravid patients diagnosed with PAS were retrospectively reviewed. The MRI features of PAS were analysed and compared using the chi-squared test, and the odds ratios (ORs) for significant risk factors for classification of PAS were identified via a multivariate logistic regression model. A receiver-operating characteristic (ROC) curve was used to calculate cut-off values and their corresponding sensitivity, specificity, and accuracy in classifying PAS.

RESULTS

We identified 3 significant risk features for classification of PAS, including placental heterogeneity (OR = 13.604), abnormal vascularization at the placental-maternal interface (OR = 9.528), and focal myometrial interruption (OR = 118.779). The significant risk features for classification of PAS were scored according to their OR values, as 3 points (OR ≥ 20), 2 points (10 ≤ OR < 20), or 1 point (OR < 10). Based on the scores of the 3 risk features, a cut-off score of 4.5 points achieved optimal sensitivity (94.3%), specificity (90%), and accuracy (92.3%) for classifying PAS in high-risk gravid patients.

CONCLUSION

Quantifying these MRI features including placental heterogeneity, abnormal vascularization at the placental-maternal interface, and focal myometrial interruption can make a classification of PAS in high-risk gravid patients.

Для цитирования: Chu Caiting, Liu Ming, Zhang Yuzheng, Yu Lingwei, Wang Dengbin, Gao Chengjin, Li Wenhua. Quantifying magnetic resonance imaging features to classify placenta accreta spectrum (PAS) in high-risk gravid patients.. Clinical imaging. 2021. DOI: 10.1016/j.clinimag.2021.04.025.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.