MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.surg.2021.04.034

Медицинская библиотека · Surgery · 2021

Predicting the need for massive transfusion: Prospective validation of a smartphone-based clinical decision support tool.

Dente Christopher J, Mina Michael J, Morse Bryan C, Hensman Hannah, Schobel Seth, Gelbard Rondi B, Belard Arnaud, Buchman Timothy G, Kirk Allan D, Elster Eric A

СтатьяПоддержка правительства СШАВалидационное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Improper or delayed activation of a massive transfusion protocol may have consequences to individuals and institutions. We designed a complex predictive algorithm that was packaged within a smartphone application. We hypothesized it would accurately assess the need for massive transfusion protocol activation and assist clinicians in that decision.

METHODS

We prospectively enrolled patients at an urban, level I trauma center. The application recorded the surgeon's initial opinion for activation and then prompted inputs for the model. The application provided a prediction and recorded the surgeon's final decision on activation.

RESULTS

Three hundred and twenty-one patients were enrolled (83% male; 59% penetrating; median Injury Severity Score 9; mean base deficit -4.11). Of 36 massive transfusion protocol activations, 26 had an app prediction of "high" or "moderate" probability. Of these, 4 (15%) patients received <10 u blood as a result of early hemorrhage control. Two hundred and eighty-five patients did not have massive transfusion protocol activated by the surgeon with 27 (9%) patients having "moderate" or "high" likelihood predicted by the application. Twenty-four of these did not require massive transfusion, and all patients had acidosis that unrelated to hemorrhagic shock. For 13 (50%) of the patients with "high" probability, the surgeon correctly altered their initial decision based on this information. The algorithm demonstrated an adjusted accuracy of 0.96 (95% confidence interval [0.93-0.98); P ≤ .001]), sensitivity = 0.99, specificity 0.72, positive predictive value 0.96, negative predictive value 0.99, and area under the receiver operating curve = 0.86.

CONCLUSION

A smartphone-based clinical decision tools can aid surgeons in the decision to active massive transfusion protocol in real time, although it does not completely replace clinician judgment.

Для цитирования: Dente Christopher J, Mina Michael J, Morse Bryan C, Hensman Hannah, Schobel Seth, Gelbard Rondi B, Belard Arnaud, Buchman Timothy G, Kirk Allan D, Elster Eric A. Predicting the need for massive transfusion: Prospective validation of a smartphone-based clinical decision support tool.. Surgery. 2021. DOI: 10.1016/j.surg.2021.04.034.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.