MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Radiation medicine · 2002

CT portography by multidetector helical CT: comparison of three rendering models.

Nakayama Yoshiharu, Imuta Masanori, Funama Yoshinori, Kadota Masataka, Utsunomiya Daisuke, Shiraishi Shinya, Hayashida Yoshiko, Yamashita Yasuyuki

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To assess the value of multidetector CT portography in visualizing varices and portosystemic collaterals in comparison with conventional portography, and to compare the visualizations obtained by three rendering models (volume rendering, VR; minimum intensity projection, MIP; and shaded surface display, SSD).

METHODS

A total of 46 patients with portal hypertension were examined by CT and conventional portography for evaluation of portosystemic collaterals. CT portography was performed by multidetector CT (MD-CT) scanner with a slice thickness of 2.5 mm and table feed of 7.5 mm. Three types of CT portographic models were generated and compared with transarterial portography.

RESULTS

Among the 46 patients, 48 collaterals were identified on CT transverse images, while 38 collaterals were detected on transarterial portography. Forty-four of 48 collaterals identified on CT transverse images were visualized with the MIP model, while 34 and 29 collaterals were visualized by the VR and SSD methods, respectively. The average CT value for the portal vein and varices was 198 HU with data acquisition of 50 sec after contrast material injection.

CONCLUSIONS

CT portography by multidetector CT provides excellent images in the visualization of portosystemic collaterals. The images of collaterals produced by MD-CT are superior to those of transarterial portography. Among the three rendering techniques, MIP provides the best visualization of portosystemic collaterals.

Для цитирования: Nakayama Yoshiharu, Imuta Masanori, Funama Yoshinori, Kadota Masataka, Utsunomiya Daisuke, Shiraishi Shinya, Hayashida Yoshiko, Yamashita Yasuyuki. CT portography by multidetector helical CT: comparison of three rendering models.. Radiation medicine. 2002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.