MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1167/tvst.14.5.13

Медицинская библиотека · Translational vision science & technology · 2025

Normative Variability in Retinal Nerve Fiber Layer Thickness: Does It Matter Where the Peaks Are?

Gowrisankaran Sowjanya, Abbasi Ashkan, Song Xubo, Schuman Joel S, Wollstein Gadi, Antony Bhavna J, Ishikawa Hiroshi

СтатьяПеревод в очереди

Аннотация

PURPOSE: Retinal nerve fiber layer thickness (RNFLT), a glaucoma biomarker, has a wide normative range affecting its sensitivity and specificity for abnormality detection. The interindividual RNFLT peak location variability contribution to this wide normative range has not been directly evaluated. The purpose of this study is to assess the effect of RNFLT peak normalization (PN) on normative variability.

METHODS

Circumpapillary RNFLT profiles at 1.7 mm radius from the optic nerve head (ONH) were re-sampled from optical coherence tomography (OCT) volumes (Cirrus HD-OCT, 200 × 200) obtained from one eye of 83 healthy individuals. Fovea-ONH axis (FOA) was calculated from corresponding scanning laser ophthalmoscope images. Supratemporal (ST) and infratemporal (IT) RNFLT peaks of each profile were aligned to respective average peak locations. Normative ranges were calculated by averaging individual profiles before and after PN (with and without FOA to horizontal image axis (HA) alignment).

RESULTS

RNFLT-PN resulted in an overall decrease in coefficient of variation (CoV) of the normative range by 4.2% (P = 0.02). CoV was reduced by more than 10% in clock-hours 10 (11.9%), 8 (10.6%), 6 (10.4%) after PN, and 7 (16.3%), 10 (11.4%), and 12 (10.4%) after PN with FOA-HA alignment. RNFLT-PN corrected for abnormality categorization because of peak misalignment in RNFLT profiles of healthy and glaucoma suspect subjects.

CONCLUSIONS

RNFLT-PN reduces normative variability, especially in the ST and IT regions.

TRANSLATIONAL RELEVANCE: RNFLT-PN reduces normative variability and improves sectoral abnormality categorization, potentially leading to better sensitivity and specificity of RNFLT measure in glaucoma detection.

Для цитирования: Gowrisankaran Sowjanya, Abbasi Ashkan, Song Xubo, Schuman Joel S, Wollstein Gadi, Antony Bhavna J, Ishikawa Hiroshi. Normative Variability in Retinal Nerve Fiber Layer Thickness: Does It Matter Where the Peaks Are?. Translational vision science & technology. 2025. DOI: 10.1167/tvst.14.5.13.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.