MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1017/s0022215106000946

Медицинская библиотека · The Journal of laryngology and otology · 2006

Thyroid surgery and recurrent laryngeal nerve monitoring.

Bailleux S, Bozec A, Castillo L, Santini J

СтатьяПеревод пока не подготовлен

Аннотация

UNLABELLED: Recurrent laryngeal nerve paralysis is a much-dreaded complication of thyroid surgery.

OBJECTIVE

To study the feasibility and the reliability of a recurrent laryngeal nerve monitoring technique.

MATERIALS AND

METHODS

This was a prospective study including 36 patients proposed for thyroid surgery with recurrent laryngeal nerve monitoring. They underwent post-operative fibre-optic laryngeal examination and speech therapist consultation.

RESULTS

Our technique of nerve monitoring showed a 98 per cent sensitivity and 86 per cent specificity.

CONCLUSIONS

Recurrent laryngeal nerve monitoring is a feasible and reliable technique. It can be used to avoid bilateral nerve injury and to increase the surgeon's confidence but not to replace a systematic nerve identification and a careful dissection.

Для цитирования: Bailleux S, Bozec A, Castillo L, Santini J. Thyroid surgery and recurrent laryngeal nerve monitoring.. The Journal of laryngology and otology. 2006. DOI: 10.1017/s0022215106000946.