BACKGROUND
Atrioventricular node ablation (AVNA) and pacemaker (PM) is performed in symptomatic atrial fibrillation (AF) unresponsive to medical treatment and percutaneous ablation. This meta-analysis evaluated results after AVNA and PM.
METHODS
Primary and secondary endpoints were early/late overall/cardiac-related mortality and early/late postoperative complications. Meta-regression explored mortality and preoperative characteristics relation.
RESULTS
We selected 93 studies with 11,340 patients: 9105 right ventricular (RV)-PM, and 2235 biventricular PM (cardiac resynchronization therapy, CRT). Malignant arrhythmia (2.5%), heart failure (2.4%), and lead dislodgement (2.0%) were most common periprocedural complications. Pooled estimated 30-day mortality was 1.08% (95%CI:0.65-1.77). At 19.9 months median follow-up (IQR: 10.3-34 months), rehospitalization (0.79%/month) and heart failure (0.48%/month) were the most frequent complications. Overall mortality incidence rate (IR) was 0.43%/month (95%CI:0.36-0.51), and cardiac death IR 0.27%/month (95%CI:0.22-0.32). No mortality determinants emerged in the AVNA CRT subgroup. AVNA RV-PM subgroup univariable meta-regression showed inverse relationship between age, ejection fraction (EF), and late cardiac death (Beta = -0.0709 ± 0.0272; p = 0.0092 and Beta = -0.0833 ± 0.0249; p = 0.0008). Coronary artery disease (CAD) was directly associated to follow-up overall/cardiac mortality at univariable (Beta = 0.0550 ± 0.0136, p < 0.0001; Beta = 0.0540 ± 0.0130, p < 0.0001) and multivariable (Beta = 0.0460 ± 0.0189, p = 0.152; Beta = 0.0378 ± 0.0192, p = 0.0491) meta-regression.
CONCLUSIONS
Solid long-term evidence supporting AVNA and pace is lacking. Younger patients with reduced LVEF% have increased follow-up cardiac mortality after AVNA RV and may require CRT. Alternative strategies to maintain sinus rhythm and ventricular synchronism should be compared to AVNA to support future treatment strategies.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.