BACKGROUND
We examined the efficacy of a novel endoscopic ligation technique with O-ring closure (E-LOC) to prevent bleeding after gastric endoscopic submucosal dissection (ESD) under antithrombotic therapy.
METHODS
This single-center prospective study involved consecutive patients who were taking antithrombotic agents and underwent gastric ESD. E-LOC was performed by anchoring the nylon loop with hemoclips on both defect edges and/or the exposed muscle layer, and using O-ring band ligation around these deployed clips. The primary outcome was post-ESD bleeding rate. Secondary outcomes were complete closure rate, procedure time, sustained closure rate, and complications.
RESULTS
48 patients were finally analyzed. The post-ESD bleeding rate was 0 %, the complete closure rate was 97.9 %, and the mean closure time was 29.9 minutes. The sustained closure rate was 95.8 % at postoperative day 2-3 and 33.3 % at postoperative day 10-11. No complications occurred.
CONCLUSION
E-LOC may be an effective option for closing mucosal defects after gastric ESD under antithrombotic therapy. However, the preventive effect on post-ESD bleeding should be further investigated in high risk groups.