Aortic valve replacement with anterior and posterior enlargement of small aortic annulus is comparable to surgery with normal annulus.

Sant'anna João Ricardo M, de Bacco Felipe W, Santánna Roberto T, Kalil Renato A K, Prates Paulo R, Nesralla Ivo A

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To compare results of aortic valve replacement in patients with normal annulus and in those undergoing anterior and posterior enlargement of a small annulus to implant a larger prosthesis.

METHODS

The study included 22 patients with enlargement of a small aortic annulus and 23 with a normal aortic annulus, with similar demographic characteristics and selected from a large surgical population. For normal annulus, simple valve replacement was performed. For annular enlargement, the posterior approach required incision in the mid portion of the non-coronary sinus, up to the anterior mitral leaflet; anterior enlargement was achieved by an incision between the left and right coronary ostium, extended to the ventricular septum for 2 cm. The aorta was reconstructed with bovine pericardium patches. The results analyzed included diameter of aortic annulus at surgery, clinical evolution (2 to 11 years of follow-up), left outflow tract obstruction and left ventricular mass (by Doppler echocardiography).

RESULTS

Enlargement increased the aortic annulus from 18.3 +/- 2.2 mm to 24.8 +/- 2.0 mm (p < 0.001), a value similar to aortic annulus considered normal: 24.9 +/- 1.5 mm (NS). For annular enlargement, the peak systolic gradient at the prosthesis decreased from 83.6 +/- 22.3 mmHg (preoperative) to 26.7 +/- 11.4 mmHg (p < 0.01) at the last evaluation. For normal annulus, a reduction from 68.2 +/- 28.7 mmHg to 32.8 +/- 16.2 mmHg occurred (p < 0.001) (final values similar between groups; NS). Left ventricular mass at the last evaluation was 147.2 +/- 45.9 for patients with enlargement and 148.1 +/- 70.4 for those with normal annulus.

CONCLUSION

Anterior and posterior aortic annulus enlargement enabled increases in annular diameter and valve prosthesis size, providing clinical and echocardiographic results similar to patients with valve replacement in a normal annulus.

Для цитирования: Sant'anna João Ricardo M, de Bacco Felipe W, Santánna Roberto T, Kalil Renato A K, Prates Paulo R, Nesralla Ivo A. Aortic valve replacement with anterior and posterior enlargement of small aortic annulus is comparable to surgery with normal annulus.. Revista portuguesa de cardiologia : orgao oficial da Sociedade Portuguesa de Cardiologia = Portuguese journal of cardiology : an official journal of the Portuguese Society of Cardiology. 2006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.