MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/s26154985

Медицинская библиотека · Sensors (Basel, Switzerland) · 2026

Developing the NewAthena X-IFU Cryogenic AntiCoincidence Detector (CryoAC): From Microfabrication Process Standardization to Cryogenic Functional Verification Toward TRL5.

Macculi Claudio, D'Andrea Matteo, Gorla Giacomo, Lotti Simone, Minervini Gabriele, Monastra Francesco, Piro Luigi, Ferrari Barusso Lorenzo, Celasco Edvige, Gatti Flavio, Grosso Daniele, Rigano Manuela, Chiarello Fabio, Torrioli Guido, Fiorini Mauro, Uslenghi Michela, Brienza Daniele, Cavazzuti Elisabetta, Grappasonni Chiara, Puccetti Simonetta, Volpe Angela, Bastia Paolo, Coimbra Artur Cardoso, Villa Francesco

СтатьяПеревод пока не подготовлен

Аннотация

The Cryogenic Anticoincidence (CryoAC) detector is a critical subsystem designed to reduce the particle background for the X-ray Integral Field Unit (X-IFU) instrument onboard the NewAthena space observatory, the next ESA X-ray Large mission. Advancing this technology to Technology Readiness Level 5 (TRL5) requires a unified validation spanning both cleanroom microfabrication repeatability and mK low temperature operational performance. This work presents the complete development cycle of the Demonstration Model 1.2 (DM 1.2), which is aimed at completing the TRL5 demonstration path featured by all the critical technologies operating simultaneously. First, single-process verification protocols were established for Iridium pulsed laser deposition, Reactive Ion Etching (RIE), and deep silicon trenching via the Bosch process. Second, three identical single-pixel prototypes were fabricated and subjected to mK characterization. Four-wire resistance measurement results confirmed a 2/3 production yield against strict design targets (TC ~100 mK). Finally, functional testing at a bath temperature of 50 mK using a VTT FAB4 SQUID readout demonstrated excellent performance, including a low-energy threshold of ~0.6 keV, a pixel power dissipation of 5.15 nW, and an energy resolution ΔEFWHM = 735 eV at 6 keV. These combined achievements successfully validate the entire manufacturing and operational baseline against all primary space mission requirements. This paper has to be considered as a review of the CryoAC technology path toward the TRL5 achievement; main findings will be reported and discussed. Details are relegated to other papers.

Для цитирования: Macculi Claudio, D'Andrea Matteo, Gorla Giacomo, Lotti Simone, Minervini Gabriele, Monastra Francesco, Piro Luigi, Ferrari Barusso Lorenzo, Celasco Edvige, Gatti Flavio, Grosso Daniele, Rigano Manuela, Chiarello Fabio, Torrioli Guido, Fiorini Mauro, Uslenghi Michela, Brienza Daniele, Cavazzuti Elisabetta, Grappasonni Chiara, Puccetti Simonetta, Volpe Angela, Bastia Paolo, Coimbra Artur Cardoso, Villa Francesco. Developing the NewAthena X-IFU Cryogenic AntiCoincidence Detector (CryoAC): From Microfabrication Process Standardization to Cryogenic Functional Verification Toward TRL5.. Sensors (Basel, Switzerland). 2026. DOI: 10.3390/s26154985.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.