DOI 10.1016/j.athoracsur.2005.07.084

Медицинская библиотека · The Annals of thoracic surgery · 2006

Prosthesis-patient mismatch after aortic valve replacement: impact of age and body size on late survival.

Moon Marc R, Pasque Michael K, Munfakh Nabil A, Melby Spencer J, Lawton Jennifer S, Moazami Nader, Codd John E, Crabtree Traves D, Barner Hendrick B, Damiano Ralph J

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The purpose of this study was to identify patient subgroups in which prosthesis-patient mismatch most influenced late survival.

METHODS

Over a 12-year period, 1,400 consecutive patients underwent bioprosthetic (933 patients) or mechanical (467) aortic valve replacement. Prosthesis-patient mismatch was defined as prosthetic effective orifice area/body surface area less than 0.75 cm2/m2 and was present with 11% mechanical and 51% bioprosthetic valves.

RESULTS

With bioprosthetic valves, prosthesis-patient mismatch was associated with impaired survival for patients less than 60 years old (10-year: 68% +/- 7% mismatch versus 75% +/- 7% no mismatch, p < 0.02) but not older patients (p = 0.47). Similarly, with mechanical valves, prosthesis-patient mismatch was associated with impaired survival for patients less than 60 years old (10-year: 62% +/- 11% versus 79% +/- 4%, p < 0.005) but not older patients (p = 0.26). For small patients (body surface area less than 1.7 m2), prosthesis-patient mismatch did not impact survival with bioprosthetic (p = 0.32) or mechanical (p = 0.71) valves. For average-size patients (body surface area 1.7 to 2.1 m2), prosthesis-patient mismatch was associated with impaired survival with both bioprosthetic (p < 0.05) and mechanical (p < 0.005) valves. For large patients (body surface area greater than 2.1 m2), prosthesis-patient mismatch was associated with impaired survival with mechanical (p < 0.04) but not bioprosthetic (p = 0.40) valves.

CONCLUSIONS

Prosthesis-patient mismatch had a negative impact on survival for young patients, but its impact on older patients was minimal. In addition, although prosthesis-patient mismatch was not important in small patients, prosthesis-patient mismatch negatively impacted survival for average-size patients and for large patients with mechanical valves.

Для цитирования: Moon Marc R, Pasque Michael K, Munfakh Nabil A, Melby Spencer J, Lawton Jennifer S, Moazami Nader, Codd John E, Crabtree Traves D, Barner Hendrick B, Damiano Ralph J. Prosthesis-patient mismatch after aortic valve replacement: impact of age and body size on late survival.. The Annals of thoracic surgery. 2006. DOI: 10.1016/j.athoracsur.2005.07.084.

Предметные рубрики MeSH