MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jmig.2017.10.040

Медицинская библиотека · Journal of minimally invasive gynecology · 2018

Extraperitoneal Para-Aortic Lymphadenectomy by Robot-Assisted Laparoscopy.

da Costa Ana Gomes, Borghesi Yves, Hudry Delphine, Faes Julie, Bresson Lucie, Narducci Fabrice, Leblanc Eric

СтатьяПеревод пока не подготовлен

Аннотация

STUDY

OBJECTIVE

To evaluate the outcomes of extraperitoneal para-aortic lymphadenectomy by robot-assisted laparoscopy.

DESIGN

A retrospective study (Canadian Task Force classification III).

SETTING

An academic institution.

PATIENTS: Twenty-three consecutive patients with gynecologic cancer who presented for para-aortic lymphadenectomy between March 2016 and May 2017 were reviewed retrospectively.

INTERVENTIONS: Extraperitoneal para-aortic lymphadenectomy by robot-assisted laparoscopy was performed.

MEASUREMENTS AND MAIN

RESULTS

Of the 23 patients reviewed retrospectively, 10 had cervical cancer, 7 had endometrial cancer, 5 had adnexal cancer, and 1 had vaginal cancer. Data regarding patient characteristics, indication for para-aortic lymphadenectomy, type of surgery (infrarenal or inframesenteric), operative time, surgical complications, number of nodes retrieved, and postoperative hospital length of stay were collected. Two patients were excluded because of early perforation of the peritoneum. In total, 21 para-aortic lymphadenectomies were performed (16 infrarenal and 5 inframesenteric). The median skin-to-skin operating time of infrarenal extraperitoneal para-aortic lymphadenectomy by robot-assisted laparoscopy was 170 minutes (range, 90-225 minutes), the median lymph node count was 18 (range, 11-38), and the median estimated blood loss was 50 mL (range, 10-600 mL). The median skin-to-skin operating time of inframesenteric extraperitoneal para-aortic lymphadenectomy by robot-assisted laparoscopy was 120 minutes (range, 90-220 minutes), the median lymph node count was 10 (range, 7-19), and the median estimated blood loss was 30 mL (range, 10-100). Intraoperative complications included 1 thermal lesion of the left genitofemoral nerve, 1 thermal lesion of the left mesoureter (a ureteral stent was placed to avoid ureteric necrosis and fistula without after effect), and 1 lesion of the inferior vena cava that was sutured by robot-assisted laparoscopy. There were 2 additional cases of perforation of the peritoneum that occurred in the infrarenal group. The median hospital length of stay was 1 day (range, 0-7 days). Three patients were readmitted for symptomatic lymphocysts.

CONCLUSION

Extraperitoneal para-aortic lymphadenectomy by robot-assisted laparoscopy provides good visualization of the operative field without arm conflict. Still, perforation of the peritoneum and symptomatic lymphocysts are a postoperative concern.

Для цитирования: da Costa Ana Gomes, Borghesi Yves, Hudry Delphine, Faes Julie, Bresson Lucie, Narducci Fabrice, Leblanc Eric. Extraperitoneal Para-Aortic Lymphadenectomy by Robot-Assisted Laparoscopy.. Journal of minimally invasive gynecology. 2018. DOI: 10.1016/j.jmig.2017.10.040.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.