JACC. Clinical electrophysiology · 2020
Multicenter Study of Dynamic High-Density Functional Substrate Mapping Improves Identification of Substrate Targets for Ischemic Ventricular Tachycardia Ablation.
СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Srinivasan Neil T, Garcia Jason, Schilling Richard J, Ahsan Syed, Babu Girish G, Ang Richard, Dhinoja Mehul B, Hunter Ross J, Lowe Martin, Chow Anthony W, Lambiase Pier D
Аннотация
OBJECTIVES: The goal of this study was to evaluate the role of dynamic substrate changes in facilitating conduction delay and re-entry in ventricular tachycardia (VT) circuits.
BACKGROUND: The presence of dynamic substrate changes facilitate functional block and re-entry in VT but are rarely studied as part of clinical VT mapping.
METHODS: Thirty patients (age 67 ± 9 years; 27 male subjects) underwent ablation. Mapping was performed with the Advisor HD Grid multipolar catheter. A bipolar voltage map was obtained during sinus rhythm (SR) and right ventricular sense protocol (SP) single extra pacing. SR and SP maps of late potentials (LP) and local abnormal ventricular activity (LAVA) were made and compared with critical sites for ablation, defined as sites of best entrainment or pace mapping. Ablation was then performed to critical sites, and LP/LAVA identified by the SP.
RESULTS: At a median follow-up of 12 months, 90% of patients were free from antitachycardia pacing (ATP) or implantable cardioverter-defibrillator shocks. SP pacing resulted in a larger area of LP identified for ablation (19.3 mm2 vs. 6.4 mm2) during SR mapping (p = 0.001), with a sensitivity of 87% and a specificity of 96%, compared with 78% and 65%, respectively, in SR.
CONCLUSIONS: LP and LAVA observed during the SP were able to identify regions critical for ablation in VT with a greater accuracy than SR mapping. This may improve substrate characterization in VT ablation. The combination of ablation to critical sites and SP-derived LP/LAVA requires further assessment in a randomized comparator study.
BACKGROUND: The presence of dynamic substrate changes facilitate functional block and re-entry in VT but are rarely studied as part of clinical VT mapping.
METHODS: Thirty patients (age 67 ± 9 years; 27 male subjects) underwent ablation. Mapping was performed with the Advisor HD Grid multipolar catheter. A bipolar voltage map was obtained during sinus rhythm (SR) and right ventricular sense protocol (SP) single extra pacing. SR and SP maps of late potentials (LP) and local abnormal ventricular activity (LAVA) were made and compared with critical sites for ablation, defined as sites of best entrainment or pace mapping. Ablation was then performed to critical sites, and LP/LAVA identified by the SP.
RESULTS: At a median follow-up of 12 months, 90% of patients were free from antitachycardia pacing (ATP) or implantable cardioverter-defibrillator shocks. SP pacing resulted in a larger area of LP identified for ablation (19.3 mm2 vs. 6.4 mm2) during SR mapping (p = 0.001), with a sensitivity of 87% and a specificity of 96%, compared with 78% and 65%, respectively, in SR.
CONCLUSIONS: LP and LAVA observed during the SP were able to identify regions critical for ablation in VT with a greater accuracy than SR mapping. This may improve substrate characterization in VT ablation. The combination of ablation to critical sites and SP-derived LP/LAVA requires further assessment in a randomized comparator study.