Quantitative evaluation of different high-density 3D mapping modes for atrial and ventricular substrate assessment of cardiac arrhythmias with the HD grid catheter.

Hohendanner Felix, Kuhlmann Stefan, Blaschke Florian, Lacour Philipp, Dimai Sanzio, Pieske Burkert, Boldt Leif-Hendrik, Parwani Abdul S

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Atrial and ventricular arrhythmias significantly contribute to morbidity and mortality of patients with cardiac disease. Ablation of these arrhythmias has shown to improve clinical outcomes, yet targeted ablation strategies rely on proper mapping capabilities. In the present study, we compare different modes of high-resolution mapping in clinically relevant arrhythmias using HD grid.

METHODS AND

RESULTS

Using the Advisor™ HD Grid Mapping Catheter in either the standard, the wave (bipolar along spline and bipolar orthogonal) or the wave diagonal setting, low-voltage areas were determined. Low-voltage was defined as local electrograms with an amplitude <0.5 mV (bipolar; atria/ventricle) or <4 mV (unipolar; ventricle). Ultra high-density mapping in 47 patients with ventricular tachycardia, ventricular premature beats, atrial fibrillation and atrial tachycardia provided reliable information for the understanding of the arrhythmia mechanism resulting in safe ablation procedures. Regions of low voltage were significantly decreased by 14 ± 2% and 31 ± 3% with wave and wave diagonal settings as compared to standard settings, respectively.

CONCLUSION

Substrate mapping and risk stratification relies on proper low voltage discrimination. Even though the Advisor™ HD Grid Mapping Catheter was safely used in all cases, the extent of low voltage areas was mapping-mode dependent.

Для цитирования: Hohendanner Felix, Kuhlmann Stefan, Blaschke Florian, Lacour Philipp, Dimai Sanzio, Pieske Burkert, Boldt Leif-Hendrik, Parwani Abdul S. Quantitative evaluation of different high-density 3D mapping modes for atrial and ventricular substrate assessment of cardiac arrhythmias with the HD grid catheter.. Journal of electrocardiology. 2020. DOI: 10.1016/j.jelectrocard.2020.10.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.